FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0516248_1234 E YOSEMITE_2015-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ❑✓ Industry Standard ❑ Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum 0 Hydrostatic <br /> F]Other(Sped) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br /> SUISKIMEM <br /> MISEEM Sump# 87 Sump# 91 Sump# Sump# <br /> Sump Diameter: 48" 48" <br /> Sump Depth: 72" 79" <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 112" 12" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 36" 38" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Fair Fair <br /> Portion of Sump Tested' 4"Above highest penetration 4"Above highest penetration 4"Above highest penetration 4"Above highest penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes [:]No ❑✓NA ❑Yes ❑No ✓❑NA ❑Yes[] No ❑NA [:]Yes []No ❑NA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fail-safe ❑yes ❑No ❑✓ NA ❑Yes ❑No ✓❑NA ❑Yes❑ No [-INA ❑Yes ❑No ®NA <br /> shutdown?" <br /> Was fail-safe verified to be No ✓ NA [:]No ❑NA [:]Yes ❑No ❑NA <br /> operational?* <br /> [:]Yes ® ❑ ❑Yes ❑No ✓❑NA ❑Yes <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 minutes 15 minutes <br /> test: <br /> Test Start Time: 10:14am 10:09am <br /> Initial Reading(R,): 0.00352 Inches 1.00706 Inches Inches Inches <br /> Test End Time: 10:29am 10:24am <br /> Final Reading(RF): 0.00498 Inches 1.00801 Inches Inches Inches <br /> Test Duration: 15 mins 15 mins <br /> Change in Reading(RF-Rt): 0.00146 0.00095 <br /> Pass/Fail Threshold or Criteria: 10.002 0.002 <br /> Test Result: ❑Pass ,❑FAil ❑✓ Pass []Fail ❑Pass ❑Fail ❑Pass ❑Fail , <br /> Was sensor removed for testing? OYes ❑No ❑NA ❑✓Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and ❑Yes ❑No ❑NA ✓❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for.failed tests) <br /> Rrz� <br /> li <br /> ",". <br /> VW,,'�,' 0 201 <br />