Laserfiche WebLink
® Integrated solutions for centra IZed , <br />single e yte vapor recovery <br />TLS Monitoring System Requirements <br />ISD is compatible with the TLS-350/EMC w/BIR, TLS -350 — — <br />Plus/EMC Enhanced, TLS-350/EMC consoles with the following <br />minimum requirements/features: A specially designed vapor flow meter accurately <br />• ECPU2 and TLS console version 25C software (or greater) <br />• RS -232 Interface, for example: a RS -232 Interface Module, a <br />Dual -Port RS-232/RS-485 Interface Module, etc. <br />• Dispenser Interface Module (DIM) <br />• Submersible Turbine Pump (STP) shutdown control hardware, <br />for example: a Four -Relay Output Interface Module, a Three <br />Output Pressurized Line Leak Control Module (must be used in . <br />conjunction with PLLD), etc <br />• TLS console must have and integral printer, probes and the <br />appropriate number of sensor interface modules <br />Alarm Table <br />The following table contains a list of warnings and alarms <br />generated by the ISD system. <br />Warning <br />Days to <br />Alarm <br />Description <br />ISD DEGRD PRESSURE <br />30 <br />Vapor Overpressure Problem <br />ISD GROSS PRESSURE <br />7 <br />Vapor Overpressure Problem <br />ISD VAPOR LEAKAGE <br />7 <br />Vapor Leakage Problem <br />ISD SENSOR OUT <br />7 <br />Sensor Problem <br />ISD SETUP <br />7 <br />Setup Problem <br />Hnn: DEGRD COLLECT <br />7 <br />Hose A/L Problem <br />Hnn: GROSS COLLECT <br />I <br />Hose Blockage or A/L Problem <br />Hnn: FLOW COLLECT <br />1 <br />Hose Blockage Problem <br />ISD VP STATUS <br />1 <br />Vapor Processor Problem <br />ISD VP PRESSURE <br />1 <br />Vapor Processor Problem <br />ISD System Requirements <br />The following table contains pricing, part numbers as well as a description for 0 <br />ISD components. <br />Part No. Description Monitored Rem(s) <br />330020-445 Vapor Flow Meter (Sensor) Kit' 1 per dispenser <br />330020-515 Vapor Pressure Sensor Kit'' 1 per station <br />331943-203 NVMEM 2 (Report Storage) 1 per console <br />330160-xxx Software Enhancement Module (SEM) 1 per console <br />'The vapor flow meter and vapor pressure sensor are intrinsically safe sensors that connect to either the Eight by <br />Smart Sensor Interface Module (P/N 329356-004) or the Seven Input Smart Sensor Module w/Embedded Pres,. <br />Sensor Interface Module (PIN 332250-001.) <br />'The vapor pressure sensor hit includes ISD system manuals. <br />Typical Installation Dispenser hydraulics cabinet <br />I I <br />The following figure I ISD Pressure Sensor <br />lin t dispenser only) / <br />shows a typical ISD case <br />installation in the base of <br />I I <br />a dispenser. <br />Pressure sensing port Vapor return line 1 <br />Ii <br />wLET Irom dispenser 1 <br />ISD Ft. Meter <br />(m va Iled anywhere 1 <br />por line above Junction box <br />shear valve) <br />Cable c stomer 1 <br />Arrow must Iii t/4. OD / supplied) 1 <br />point down rigid tubing <br />as required <br />_ I <br />Seal on <br />P Vapor return line (customs, 1 <br />OUTLET drain t/4' shear valvesuPP ) <br />Flow meter eM vie per 12' <br />horizontal ® ®Conduit to <br />® TlS Console <br />Top of pedestal island _ <br />�® Qooe ^7 jj1 <br />0 " o t/® Ci �I A test port is required tor <br />I .Q introducing liquid during Flow Meter and Pressure �. <br />Q 0 d O <br />TP -201A dynamk Sensor wiring may share <br />M0 Q ,6 0 Q O O7 /Q, I backpressure test. the same conduit to console dl <br />61. Q Q 0 / \ 1 �2' or 3" common main vapor return line <br />Z'.61 `7o 1 Dispenser sump <br />For more information call <br />1-888-561-7942 <br />\/ C C © 2005 Veeder-Root Company • 125 Powder Forest Drive • Simsbury, CT 06070 • USA <br />Y G G Telephone: 860-651-2700 • Fax 860-651-2719 • vivvw.veeder.com <br />I V t' nr\' n_ ­ns -_01: n; P n,;,,,,-,1 ;,, 1 ` <br />