1129
>
2200 - Hazardous Waste Program
>
PR0513664
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 11:28:33 AM
Creation date
6/4/2020 4:38:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0513664
PE
2226
FACILITY_ID
FA0005307
FACILITY_NAME
HOLZ RUBBER CO
STREET_NUMBER
1129
Direction
S
STREET_NAME
SACRAMENTO
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04528008
CURRENT_STATUS
01
SITE_LOCATION
1129 S SACRAMENTO ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Hazardous Waste Contingency Plan <br /> Holz Rubber Company <br /> 2 . 2 . 5 Other Response Actions — 40 CFR 262 . 265 (e) , (f) , 22 CCR 66264 . 56 (e) <br /> During the emergency , the Emergency Coordinator will take all reasonable measures necessary to <br /> ensure that fires , explosions , or releases do not occur, recur, or spread to other hazardous <br /> materials /waste or other parts of the facility. These measures include , where applicable , collecting and <br /> containing released waste, and removing or isolating containers . <br /> 2 . 2 . 6 Follow-up Procedures , 22 CCR 66264 . 56 (9) <br /> 2. 2. 6. 9 Recovery and Disposal — 40 CFR 262. 265 0, (b) <br /> Immediately after the spill , the Emergency Coordinator will arrange for the collection and <br /> management of recovered wastes , contaminated soil or water, and any other waste materials that <br /> resulted from the emergency. <br /> Spilled material must be transferred to appropriate storage containers as soon as safely possible . <br /> Cleanup will consist of collecting as much of the spill materials as possible to avoid any future <br /> contamination of sewers , ponds , or waterways . All contaminated materials are to be placed in labeled , <br /> DOT- approved waste containers . Care will be taken not to mix the spilled material with incompatible <br /> materials . Upon completion of an emergency response , any resulting hazardous waste will be tested <br /> for waste characterization and shipped for disposal to an approved landfill or disposal facility. <br /> 2. 2. 6. 2 Follow Up Not fcalion and Repafin; — 40 CFR 262. 265 (i), 22 CCR 66264. 56U) <br /> If an incident requires the implementation of this Contingency Plan , the Emergency Coordinator will <br /> note in the operating record the time , date , and details of the incident . The Emergency Coordinator <br /> will submit a written report on the incident to the Regional administrator within 15 days of the <br /> incident. The report will include the following: <br /> • Name , address , and telephone number of the owner / operator <br /> • Name, address , and telephone number of the facility <br /> • Date, time , and type of incident <br /> Name and quantity of material (s) involved <br /> • Extent of injuries , if any <br /> • Assessment of actual or potential hazards to human health or the environment , where this is <br /> applicable <br /> • Estimated quantity of recovered materials that resulted from the incident <br /> I <br /> The following documents are available to be used as reference for release reporting: <br /> 0 " Spill Response Notification Form" (Appendix E) <br /> 3 . Additional Plan Contents <br /> This section provides information on coordination agreements , emergency coordinator contact <br /> information , emergency equipment, evacuation plans , and inspections . <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.