My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0008985
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TOSTE
>
2450
>
3500 - Local Oversight Program
>
PR0545734
>
ARCHIVED REPORTS_XR0008985
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2020 2:07:40 PM
Creation date
6/5/2020 1:25:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008985
RECORD_ID
PR0545734
PE
3528
FACILITY_ID
FA0010191
FACILITY_NAME
TRACY-PONTIAC-CADILLAC-GMC TRUCK
STREET_NUMBER
2450
STREET_NAME
TOSTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
238020-06
CURRENT_STATUS
02
SITE_LOCATION
2450 TOSTE RD
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Quarterly Report - First Quarter 2001 <br /> Former Curtiss Pontiac-Buick <br /> 2450 Toste Road, Tracy, California <br />' 1.0. INTRODUCTION <br /> At the request of Mr Joe Toste, Advanced GeoEnvironmental, Inc (AGE) has prepared this <br /> quarterly report for 2450 Toste Road, Tracy, California (the site) The scope of work included <br /> sampling ten ground water monitoring wells, data analysis and preparation of this report The site <br /> Isetting is illustrated in Figure i A plan view of the site is illustrated in Figure 2 <br /> A summary of previous investigations at the site is included in Preliminary Investigation and <br /> Evaluation Report(PIER),prepared by AGE, dated 15 August 1997 and Quarterly Report,prepared <br /> by AGE, dated 18 September 1997 Ground water monitoring data collected from momtonng well <br /> MW-3,which is part of the underground storage tank(UST)release investigation at 2420 Grant Line <br /> I Road, is included in this investigation to delineate the down gradient extent of the dissolved <br /> hydrocarbon plume and to determine ground water flow direction and gradient Quarterly monitoring <br /> data from February 1998 to the present is summarized in Tables 1 and 2 in this report <br /> 2.0. PROCEDURES <br /> Field procedures were performed in accordance with Central Valley Regional Water QualityControl <br /> I Board (CVRWQCB) and Sari Joaquin County Public Health Services - Environmental Health <br /> Division (PHS-EHD) guidelines for subsurface investigations of underground storage tank (UST) <br /> sites and sampling ground water monitoring wells <br /> 2 1 GROUND WATER DEPTH MEASUREMENT AND PURGING <br /> On 30 January 2001, a Solmst water level meter was used to measure the depth to ground water in <br /> each well relative to the top of the well casing After ground water depth measurements were <br /> I collected,monitoring wells MW-1 through MW-7 and MW-3 at 2420 Grant Line Road (GLMW-3, <br /> in this report)were purged using a two-stage submersible pump A minimum of three casing-water <br /> volumes of water were purged from each well, excluding monitoring wells MW-3 and MW-7 The <br /> actual purge volumes were as follows <br /> • Four to six gallons of water were evacuated from wells GLMW-3, MW-2B, and MW-3 <br /> through MW-6 <br /> • Ten to twelve gallons of water were purged from MW-1A and MW-2A <br /> • Monitoring wells MW-3 and MW-7 were pumped dry after three gallons and six gallons of <br /> water had been purged, respectively <br /> Advanced GeoEnvzronmentai inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.