Laserfiche WebLink
Woldearegay, Shewit - Tassew <br /> From : Nso, Paul <br /> Sent : Tuesday, May 12, 2020 3 :41 PM <br /> To. Woldearegay, Shewit-Tassew <br /> Subject: FW: yesterday' s inspection report - 3725 N . Tracy, Tracy - Summarized <br /> Attachments : Tracy Shell_UST Plan . pdf <br /> From : Campigli , Gina [ ma ilto : Gina . Cam pigli@stantec . com ] <br /> Sent : Friday, January 3, 2020 11 : 47 AM <br /> To : Debbie Watts ; Kristina Daines; Maria Guarnelli <br /> Cc : Chittal Shah <br /> Subject : RE : yesterday's inspection report - 3725 N . Tracy, Tracy - Summarized <br /> Hi Kristina , <br /> Stantec responses- <br /> 105 - 1 agree with Debbie ' s comments but will change to appease the inspector unless you say otherwise . <br /> 115 - Rita Martinez is listed on the Designated Operator form submitted in CERS on 2/5/2019 . <br /> 205 - The UST Response Plan in CERS is current and was uploaded 1/4/2018 unless Juliet Ussey is no longer the Area <br /> Manager for this location ? <br /> I have attached a copy of the UST Plan to this email to verify that the UST Response Plan and Designated Operator Form <br /> is current with the information we have on file . <br /> Thank you and please let me know if there is anything else I can help with . <br /> 105 — CCR 2632 (d ) ( 1 ) , 2634 (d ) Failed to have an approved UST monitoring plan . <br /> Monitor Plans — Stantec to Handle — I personally disagree in the Simplicity vs TLS350 ( It is a TLS 350, but noted as <br /> Simplicity as years ago , that' s who Shell Oil used to monitor Alarms ) — I personally would look at having a Discussion <br /> regarding that . You can even use the LG113 as the back- up to that argument as LG113 references TLS350' s, but not <br /> Simplicity' s ( maybe get a more experienced CUPA Inspector involved ) — I would ask to have this removed from the <br /> report <br /> 115 — CCR 2715 ( a) ( 1 ) ( B ) , 2715 (a) (3 ) " Designated Underground Storage Tank Operator Identification Form " not submitted <br /> within 30 days <br /> Rita has been conducting DO Inspections for over a year so Stantec likely provided notification over a Year ago — <br /> with proof from Stantec ( I would ask for this to be removed ) <br /> 201 — CCR 2712 ( b ) ( 1 -2 ) Failure to maintain monitoring , maintenance , and follow up action records . <br /> We' ll swing by later on this Afternoon to see if we can locate the results on site and take a Picture if we find <br /> them . If we don ' t locate them , then we ' ll leave them at the site <br /> 205 — 205 CCR 2712 ( i ) , 2634 (e) Failure to submit a current UST Response Plan and have it available onsite . <br /> Response plan — Stantec to Handle <br />