My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2020 1:10:21 PM
Creation date
6/10/2020 11:46:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231463
PE
2361
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
01
SITE_LOCATION
1257 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AMENDED <br /> SAN )OAQUIN jzjs `11'211IEnvironmental Health Department <br /> —COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> AHMEDS SONS INC 1257 W YOSEMITE AVE, MANTECA April 10, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> -Section I <br /> The DO failed to write the CERS ID <br /> -Section VI <br /> The OWNER/OPERATOR failed to provide a name, signature, and date within 48 hours of receiving the DO report <br /> under the ACKNOWLEDGMENT OF COMPLIANCE ISSUES section. <br /> -Section VII <br /> The DO fail to mark No for the question"Has each follow-up action of section III from the previous inspection been <br /> completed appropriately?" <br /> IX <br /> The DO failed to mark Yes, No, or N/A to the question"Are all sensors in under-dispenser containment located to <br /> detect a leak at the earliest opportunity?" <br /> -Section X <br /> The DO failed to mark NO under the question"Has the overfill prevention equipment inspection been completed <br /> within the past 36 months?"The overfill prevention equipment inspection has not been completed. <br /> The DO failed to mar YES, NO or N/A under the question"Has the line tightness testing been completed within the <br /> required timeframes?"and"Has the tank tightness testing been completed within the required timeframes?" <br /> -Section XI <br /> The DO failed to mark Yes or No to the question"Have all individuals performing facility employee duties received <br /> the required facility employee training within the past 12 months?" <br /> During the designated operator inspection,the designated operator shall review the alarm history for the previous <br /> month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br /> history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br /> performing inspections at least once every 30 days at this facility and are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class II. <br /> 211 CCR 2715(c)(2) No employee present that were trained in the operation and maintenance of the UST system by a <br /> DO. <br /> The designated operator employee training for Asim Ahmed was not performed. The designated operator shall train <br /> facility employees for which he or she is responsible in the proper operation and maintenance of the UST system <br /> once every 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> The designated operator was on site and was able to perform the training while the inspector was on site to correct <br /> this violation. <br /> This was corrected on site. <br /> This is a repeat violation, Class ll. <br /> FA0003707 PR0231463 SCO01 04/10/2019 <br /> EHD 23-01 Rev.09128/2018 Page 6 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.