COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2023 9:28:40 AM
Creation date
6/10/2020 4:42:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AMENDEDEnvironmental Health Department <br /> SAN JOAQUIN <br /> - c o u r�A T Y - ._._ - - <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date: <br /> WESTERN FOOD & FUEL 1 3032 E WATERLOO RD , STOCKTON December 11 , 2018 <br /> UST System Observations <br /> 314 HSC 25290. 1 , 25290. 21 Failed to have secondary containment or secondary containment not tight n V ❑ R o COS <br /> 25291 <br /> 315 HSC 25291 (e) Water In secondary containment not removed , analyzed, and properly disposed of (pre-Jul 2003) ❑ V ❑ R a COS <br /> 316 HSC 25290. 1 (c3), Secondary containment not constructed to prevent water intrusion (after Jul 2003) ❑ V OR o COS <br /> 25290.2(c3) <br /> 317 CCR 2636, 2643(c) (1 ) , Line leak detector (LLD) not installed o V o R o COS <br /> 2666(f) <br /> 318 CCR 2636(0(2) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch ■ V ■ R ■ COS <br /> 319 CCR 2635, 2637. 1 , No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested n V OR o COS <br /> 2665, 2712 <br /> 320 CCR 2635, 2637.21 Failure to comply with the installation, inspection , or record keeping of the overfill prevention ■ V o R ■ COS <br /> 2665l2712 <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden ❑ V ❑ R o COS <br /> 322 HSC 25281 ,6(a) Unburied below grade emergency generator system failed to meet exemption status o V o R o COS <br /> 323 HSC 25263.5(a) Unburied below grade UST system failed to meet exemption status o V o R o COS <br /> 324 CCR 2717. 1 (g) Tampered with red lag o V o R o COS <br /> 325 CCR 2717, 1 (f) Deposited petroleum into a red tagged UST o V o R o COS <br /> 326 HSC 25299(a) (9) Tampered with or disabled leak detection devices or alarms o V o R n COS <br /> 327 CCR 2631 . 1 UST system not compatible with the substance stored o V o R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V o R o COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements o V ❑ R o COS <br /> 330 CCR 2636(f) 7 2666(c) , No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm o V o R o COS <br /> 2666(f) <br /> 331 CCR 2630(d), 2641 (a) Liquid does not flow into the sump in the event of a leak (i.e. , failure to remove test boot). o V o R o COS <br /> 332 CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards o V ❑ R o COS <br /> 2666(b&e) <br /> 333 CCR 2635, 2636(b), Failure to comply with the cathodic protection system requirements o V n R o COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair o V o R o COS <br /> 335 CCR 2630, 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an Independent third-party o V OR o COS <br /> 2644. 1 <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) 1 Suction piping not properly sloped or incorrectly located check valve ❑ V OR o COS <br /> 2641 (b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems (pre-Jan 1984). o V OR o COS <br /> 403 CCR 2643(d), 2661 (f) Failure to conduct 0. 1 gph lest for single-walled conventional suction systems (pre-Jan 1984) ❑ V OR o COS <br /> 404 CCR 2643(e) , 2661 (f) Biennial 0. 1 gph line integrity test for single-walled gravity piping not performed (pre-Jan 1984) o V ❑ R o COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> FA0002127 PR0231758 SC001 12/11 /2018 <br /> EHD 23-01 Rev, 09/28/2018 Page 3 of 8 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.