COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1151
>
2300 - Underground Storage Tank Program
>
PR0231429
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2021 9:57:16 AM
Creation date
6/11/2020 10:06:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231429
PE
2361
FACILITY_ID
FA0000819
FACILITY_NAME
ONE STOP MARKET*
STREET_NUMBER
1151
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
21641001
CURRENT_STATUS
01
SITE_LOCATION
1151 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health DepartmentUnderground Storage Tank Program Inspection ReportDate:December 15, 2020Facility Address:1151W LOUISE AVE, MANTECAFacility Name:ONE STOP MARKET*SUMMARY OF VIOLATIONS(CLASS I, CLASS II, or MINOR - Notice to Comply)RemarksItem #208CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. OBSERVATION: The designated operator failed to document all the alarms from the attached alarm history on the 10/26/2020 designated operator inspection report and failed to check that they were responded to appropriately. The missing alarms include: L1 Disp1-2 fuel alarm of 10/15/2020, L2 Disp3-4 fuel alarm of 10/15/2020, L3 Disp5-6 fuel alarm of 10/15/2020, L4 Disp7-8 fuel alarm of 10/15/2020, L5 87 STP sump fuel alarm of 10/15/2020, L6 Diesel STP sump fuel alarm of 10/15/2020. L7 91 STP sump fuel alarm, L8 87 Annular apace fuel alarm 0f 10/15/2020, L9 diesel annular space fuel alarm of 10/15/2020,and L10 91annular space fuel alarm of 10/15/2020 REGULATION GUIDANCE: During the inspection, the designated operator shall review the alarm history since the previous inspection, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any alarms to the inspection report. CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of the required information on the reports.This is a minor violation.Overall Inspection Comments:Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement documenting the corrective actions that have been or will be taken for each violation, and any supporting paperwork, by 01/14/2021 .To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an appointment, please call (209) 468-3420.Documents provided during inspection: Return to compliance certification form, corrective action statement form and a list of CUPA approve free training classes.AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS FACILITY BACK INTO COMPLIANCE.THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. Received by: Inspector Phone: PAUL NSO, EH Specialist Inspector:December 15, 2020 Date:Printed Name and Title:Ammy Kamboj, Manager(209) 616-3049FA0000819 PR0231429 SC001 12/15/2020EHD 23-01 Rev. 9/16/2020Underground Storage Tank Program OIRPage 6 of 61868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.