My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
824
>
2300 - Underground Storage Tank Program
>
PR0231459
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2020 7:06:55 PM
Creation date
6/11/2020 10:34:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231459
PE
2361
FACILITY_ID
FA0003677
FACILITY_NAME
DIAMOND GAS AND FOOD MART
STREET_NUMBER
824
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118003
CURRENT_STATUS
01
SITE_LOCATION
824 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for DIAMOND GAS AND FOOD MART as of May11, 2020 . <br /> Open violations from June 04 , 2019 inspection <br /> Violation #306 - Monitoring equipment is not installed or maintained to detect a leak at the earliest <br /> opportunity. <br /> The UCD 7/8 , and UDC 3 /4 sump sensor was raised approximately 2-3 inches off the lowest point of the sump and <br /> not located to detect a leak at the earliest opportunity. Liquid was observed in UDC 7/8 as well as a leaky 91 product <br /> meter. Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The <br /> sensor was relocated to the lowest point of the sump by the service technician . Ensure that all monitoring <br /> equipment is maintained to detect a leak at the earliest opportunity. <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #313 - Failure to construct, operate , and maintain primary containment as product-tight. <br /> In UDC 7/8 , 91 product fuel meter was observed to leaking , indicating a leak in the primary piping . All primary <br /> containment for the UST system must be tight. Immediately have a properly licensed , trained , and certified <br /> contractor repair or replace the failed component under permit and inspection of the EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Page 4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.