My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 3:42:08 PM
Creation date
6/11/2020 2:09:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM ( Page 1 of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑ Six Month Test N 36 Month Test <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10181913 07/08/2020 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Shell <br /> Business Site Address FL <br /> ity ZIP Code <br /> 16500 S . Harladn Road athro , CA 195330 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification.) Phone # <br /> Marco Alejos (888) 500 - 2435 Ext, 2 <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 958763 8415074 04/27/2021 <br /> III . SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> Tank ID : (By tank number, stored product, etc.) A 87 B 91 <br /> Tank Containment <br /> Tightness Test Result N Pass ❑ Fail ❑ NA N Pass ❑ Fail ❑ NA <br /> Product Piping Containment <br /> Tightness Test Result ❑ Pass N Fail ❑ NA ❑ Pass N Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> Communication Test Result ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> Communication Test Result ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> Communication Test Result ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> Turbine / Product Piping Sump <br /> Tightness Test Result N Pass ❑ Fail ❑ NA N Pass ❑ Fail ❑ NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> Vent / Transition Sump ID: a b C d <br /> Tightness Test Result ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> UDC ID : 1 1 - 2 2 3-4 3 5-6 4 7- 8 <br /> Tightness Test Result N Pass ❑ Fail ❑ NA N Pass ❑ Fail ❑ NA N Pass ❑ Fail ❑ NA ❑ Pass N Fail ❑ NA <br /> UDC ID : 5 6 7 8 <br /> Tightness Test Result ❑ Pass ❑ Fail JNNA <br /> El Pass El Fail N NA ❑ Pass El Fail N NA E] Pass E] Fail N NA <br /> UDC ID : 9 10 11 12 <br /> Tightness Test Result F71 Pass El Fail ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA ❑ Pass ❑ Fail N NA <br /> All items marked "Fail' or "N/A " must be explained in their respective "COMMENTS" section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations , title 23 , <br /> division 3 , chapter 16 , section 2637 and all the information contained herein is accurate . <br /> UST Service Technician Signature <br /> 14"1 , <br /> 1 <br /> CERS = California Environmental Rel cation, UST = Underground storage tank, ICC = International Code Council, <br /> NA = Not applicable, UDC = Under-dispenser containment <br />