Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for MORADA CHEVRON FAST N EASY#60* as of October 07, <br /> 2020. <br /> Open violations from April 11, 2019 inspection <br /> Violation#318-No spill bucket,failed to contain 5 gallons, no means to keep it empty,or failed to be <br /> tested. <br /> The 91 north spill container failed to have a minimum capacity of five gallons.All spill containers shall have a <br /> minimum capacity of five gallons. Immediately contact a properly licensed,trained, and certified contractor to repair <br /> or replace the spill container under permit and inspection of the EHD. <br /> The 87 spill container failed when tested.All spill containers shall have a minimum capacity of five gallons and be <br /> capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue deposition of <br /> petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, aand certified <br /> contractor under permit and inspection by EHD. If the spill container cannot be replaced immediately,there is a <br /> possibility that the 87 UST system may be red tagged to prevent fuel inputs. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#318-No spill bucket,failed to contain 5 gallons, no means to keep it empty,or failed to be <br /> tested. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Open violations from April 11, 2019 inspection <br /> Violation#302-Monitoring equipment is not installed or maintained to detect a leak at the earliest <br /> opportunity. <br /> The 91 north STP sump sensor was not located to detect a leak at the earliest opportunity. The sensor was located <br /> on the side opposite the fuel piping and was placed over a foot south of the lowest point. Monitoring equipment <br /> shall be maintained to be able to detect a leak at the earliest possible opportunity. The sensor was relocated to the <br /> lowest point of the sump by the service technician. Ensure that all monitoring equipment is maintained to detect a <br /> leak at the earliest opportunity. <br /> Page 12 of 13 <br />