Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for MORADA CHEVRON FAST N EASY#60* as of October 07, <br /> 2020. <br /> Open violations from April 11, 2019 inspection <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#303-Liquid does not flow into the sump in the event of a leak(i.e.,failure to remove test boot).. <br /> The plug under the clamshell on the 91 south STP sump product piping was not removed. The schrader valve was <br /> open, but was pointed up. Any potential release from the primary containment into the secondary containment in <br /> the 91 south piping does not flow into a collection sump. All secondary containment systems shall be sloped so that <br /> all releases will flow to a collection sump located at the low point of the underground piping. Immediately contact a <br /> properly licensed,trained, and certified contractor to ensure that any releases in the 91 south piping flows into the91 <br /> south piping sump. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#318-No spill bucket,failed to contain 5 gallons, no means to keep it empty,or failed to be <br /> tested. <br /> The 91 north spill container failed to have a minimum capacity of five gallons. All spill containers shall have a <br /> minimum capacity of five gallons. Immediately contact a properly licensed, trained, and certified contractor to repair <br /> or replace the spill container under permit and inspection of the EHD. <br /> The 87 spill container failed when tested. All spill containers shall have a minimum capacity of five gallons and be <br /> capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue deposition of <br /> petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, and certified <br /> contractor under permit and inspection of the EHD. If the spill container can't be replaced immediately,there is a <br /> possibility that the 87 UST system may be red tagged to prevent fuel inputs. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Page 13 of 13 <br />