My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2551
>
2300 - Underground Storage Tank Program
>
PR0231659
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2021 9:32:37 PM
Creation date
6/11/2020 3:46:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231659
PE
2361
FACILITY_ID
FA0003849
FACILITY_NAME
Verizon Business: MANTECA
STREET_NUMBER
2551
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
19801005
CURRENT_STATUS
01
SITE_LOCATION
2551 E LOUISE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PERP 1200 - 12 <br /> 6 . 2. 1 Purpose . This method is used to test the 5. If the spill bucket is found to have cracks , loose <br /> integrity of single-walled spill buckets or the pri parts or separation of the bucket from the fill <br /> mary containment of secondarily contained spill pipe , it is not considered to be liquid-tight. This <br /> buckets . visually indicates a test failure. <br /> 6. 2 . 2 Description of Test. The spill bucket is NOTE: If the fill cap is not included in the <br /> filled with water. The water level is measured at the spill bucket test and/or the cap is not tight , it <br /> beginning and end of the test. could be the source of potential fuel contami- <br /> 6 . 2 . 3 Test Equipment. Test equipment shall nation from water intrusion . <br /> 0 <br /> include : <br /> NOTE: Before permanently plugging, ensure <br /> • water; that local regulations allow the drain valve to <br /> • measuring stick that is accurate to within 1 / 16 be permanently plugged. <br /> (0.063 ) inch and of sufficient length ; <br /> • plumber 's plug (appropriate size, if used) ; 6.2 . 5 Test Procedure. <br /> • stopwatch or other time-measurement device 1. Add water to the spill bucket to a level within <br /> capable of measuring a 1 -second increment . 1 .5 inches of the top of the spill bucket. Allow <br /> the water to settle for 5 minutes before the initial <br /> 6. 2 . 4 Preparation . water level measurement is taken . <br /> 1. Care should be taken when conducting the test 2 . Place the measuring stick vertically at the lowest <br /> in the rain or during freezing weather condi- point in the spill bucket and extending above the <br /> tions . water level to allow for an accurate measure- <br /> 2. Remove and properly dispose of any liquid and ment to be taken . The location of the measuring <br /> debris (leaves , sediment and trash) in the spill stick must remain the same for each water level <br /> bucket. Clean the spill bucket and examine it for measurement. Document the initial water level <br /> damage, defects or improperly installed compo- measurement as measured from the bottom of <br /> nents . If there are loose components (e.g., loose the spill bucket. Alternative measurement meth- <br /> band clamps or bolts) , tighten these items before ods may be used provided that measurement to <br /> conducting the integrity test. If there are items 1 / 16 (0 .063 ) inch can be made . <br /> that must be repaired or replaced (e.g. , deterio- 3 . Take all precautions to prevent the water level <br /> rated gaskets/seals or drain valves) , notify the from being disturbed during the duration of the <br /> owner/operator. test. <br /> 3. Examine the fill cap and adapter fitting for 4. After 1 hour, document the ending water level <br /> loose, missing or damaged parts, and make measurement . <br /> necessary repairs. Complete any repairs before S. Upon completion of the test, remove and dis- <br /> putting water in the spill bucket. Make sure that pose of the water according to Section 6. 7 , and <br /> the seal on the fill cap is present and in good dry the inside of the spill bucket before returning <br /> condition . The cap must fit securely and be leak- it to services <br /> tight on the riser. The water level during the test <br /> typically will be above the cap, so a leaking cap 6 .2 . 6 Pass/ Fall Criteria . If the water level has <br /> will result in a failed test. As an alternative to a dropped less than 1 /8 (0 . 125 ) inch , the spill bucket <br /> tight fill cap, use a plumber 's plug in the fill riser passes the integrity test. <br /> if approved by the authority having jurisdiction <br /> (AHJ) and tank owner. If the water level has dropped 1 /8 ( 0. 125 ) inch or <br /> 4. The spill-bucket drain valve, if present, must greater, the spill bucket fails the integrity test. <br /> be leak-tight to pass the test . If it is not leak- <br /> tight, it may be possible to simply remove and <br /> permanently plug the drain valve. However, if <br /> you choose to permanently plug, ensure that the <br /> local regulations allow this modification . <br /> ® pei , org <br />