Laserfiche WebLink
TEST INSTRUCTIONS Socket <br /> POPPET&FLOAT MOVEMENT adaptor _ <br /> FOR TESTABLE MODELS ONLY <br /> TOOLS NEEDED FOR TESTING: <br /> 1. 1!4x square drive extension or 318"square drive ex- <br /> tension with 31V to 1!4"socket adapter. '� l l 1 { ( i <br /> 2. Torque wrench 1 114"or 318"square drive ratchet <br /> wrench, <br /> 3. Pipe dope. `'.__T <br /> 4. Flashlight(optional). <br /> Open Poppet Closed Poppet <br /> TEST STEP 1: Test Figure 7 <br /> Remove spill container cover and fill cap from fill adapt- <br /> er and look down into the tube and make sure no debris pull on extension and <br /> or foreign objects are present. If debris or foreign ob- socket adaptor <br /> jects are present take appropriate steps before proceed- <br /> ing. Look down into the tube and ensure poppet is <br /> completely rotected by the deflection shield. See Test ; - <br /> Figure 1. If poppet is exposed and tank is not full the :-----f <br /> overfill valve should be replaced. A flashlight may help <br /> when inspecting the tube. <br /> TEST STEP 2: _ <br /> Unthread the socket adaptor assembly from the inlet <br /> tube using a 114 square drive extension and wrench. <br /> The extension will attach to the socket adaptor. Secure i..R <br /> all tools to ensure they don't fall into the tank or valve. <br /> With the extension still attached pull on the socket - <br /> adaptor and cable assembly and ensure float and pop- <br /> pet move/function properly. It should only require 3ff <br /> to 4"of movement and less than 5 lbs of force in order -- -- <br /> to actuate the float and poppet. When looking down . <br /> into the upper tube ensure poppet is visible and moves <br /> into the flow path(see Test Figure 1 &2)when socket Open <br /> adaptor is pulled and resets properly when socket adap- Poppet Closed <br /> for is released. If poppet does not actuate freely take Poppet j Float moves <br /> appropriate steps to correct, ` up <br /> TEST STEP 3: _ <br /> I <br /> Apply pipe dope to the socket adaptor threads. Pipe i` r <br /> dope should be a non-hardening gasoline resistant pi pe <br /> thread seal compound. Make sure poppet and float <br /> have reset properly and are not visible then install sock- <br /> et adaptor and torque to 3.5 ft-Ibs(42 in-lbs)minimum <br /> to 5.0 ft-lbs(60 in-lbs)maximum. After installing socket <br /> adaptor,to ensure vapor tightness,DPW recommends <br /> conducting pressure testing per CARE TP201.1 D. Some Test Figure 2 <br /> areas may require pressure testing of overfill valve per <br /> CARE TP201.1 D to ensure valve is vapor tight. If the <br /> drop tube fails pressure testing it may be necessary to <br /> check the seal at the poppet adaptor threacts. Reinstall <br /> fill cap and spill container cover after testing. <br /> 17 <br />