Laserfiche WebLink
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />April 10, 2019 <br /> Facility Address: <br /> 14000 E HWY 88 , LOCKEFORD <br /> Facility Name: <br /> H&S Energy Products,#3038 <br />Other Violations <br /> 2010 □ V □ R □ COSUnlisted General violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 102 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />In the 87 product and 91 product UST Tank Information forms are not current in CERS. The under tank construction <br />for overfill protection it states YES for "audible and visual alarm" however no external audible and visual alarms <br />were not observed at the time of inspection. Any change of information must be updated in CERS within 30 days of <br />the changes. Immediately log into CERS, update the required information, and submit for review by the EHD. <br />This is a repeat violation, Class II. <br /> 104 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. The site listed sensor 208 installed in the UDCs <br />as their means of monitoring the under dispenser containment sumps, however the site has Bravo floats and chains <br />as their primary means of monitoring the UDC, furthermore, the site stated in their monitoring plan that records of <br />tank integrity testing were kept on site. When asked the environmental contact Desiz Burns stated that the site did <br />not have tank integrity testing and that it would be removed from their monitoring plan. The monitoring plan must be <br />uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make the <br />necessary changes, and submit for review by the EHD. <br />This is a repeat violation, Class II. <br /> 203 CCR 2712(b)(1-2) Failure to maintain monitoring, maintenance, and follow up action records. <br />Maintenance and monitoring records for the last three years were not found on site. Records missing are the <br />following: Secondary containment test result from 2017, monitoring system certification from 2016, work order <br />B46999 for the replacement of L7- UDC 1/2 208 sensor. These records shall be maintained on site for at least <br />three years. Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment <br />calibration and maintenance records; (3) results of any visual observations; (4) results of sample analysis performed <br />a lab or in the field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or <br />other test results; (6) results of inventory readings and reconciliations. The environmental contact, Desiz Burns, <br />emailed a copy of the missing maintenance records to site while the inspector was on site. Maintain all maintenance <br />and monitoring records for the last three years on site and submit copies to the EHD. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br /> 205 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a repeat violation, Class II. <br />FA0000091 PR0231631 SC001 04/10/2019 <br />EHD 23-01 Rev. 9/16/2020 Underground Storage Tank Program OIRPage 4 of 8 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD