COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
900
>
2200 - Hazardous Waste Program
>
PR0513643
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2020 10:32:48 PM
Creation date
6/16/2020 9:51:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0513643
PE
2227
FACILITY_ID
FA0003769
FACILITY_NAME
TERESI TRUCKING LLC
STREET_NUMBER
900
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905026
CURRENT_STATUS
01
SITE_LOCATION
900 1/2 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TERESI TRUCKING LLC 900 E VICTOR RD, LODI July 31, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 115 CCR 66262.42(a)(b)(d)Failed to comply with uniform hazardous waste manifest exception requirements. <br /> Manifest numbers 017381306JJK(3/27/18)and 018790481JJK(6/28/18)were found without a signed off copy from <br /> the destination facility. Hazardous waste generators shall retain copies of all manifests signed off by the destination <br /> facility on site for three years and have them readily available for review. If the generator did not receive a copy of <br /> the manifest with the handwritten signature of the owner or operator of the facility to which the generator's waste <br /> was submitted within 35 days of the date the waste was accepted by the initial transporter,the generator shall <br /> contact the transporter and/or the owner or operator of the designated facility to determine the status of the waste. <br /> If the generator did not receive a copy of the signed off copy of the manifest within 45 days of the date that the <br /> waste was accepted by the initial transporter, the generator shall submit an Exception Report that includes a legible <br /> copy of the missing manifest, and a cover letter signed by the generator explaining the efforts to locate the <br /> hazardous waste and the results of those efforts. Exception reports shall be submitted to: <br /> DTSC Report Repository <br /> Generator Information Services Section <br /> P.O. Box 806 <br /> Sacramento, CA 95812-0806 <br /> Immediately locate a copy of the missing manifests or prepare and submit an exception report to DTSC. Submit to <br /> the EHD a copy of the signed off copy of the manifests or a copy of the exception report submitted to DTSC. <br /> This is a minor violation. <br /> 118 CCR 66265.16(d) Failed to maintain complete personnel training records. <br /> Employee training records for the management of hazardous waste were incomplete.Todd Teresi stated that there <br /> are five employees that manage the facility's hazardous waste.Todd provided a"Hazardous Materials Emergency <br /> Response Training" page for one employee Michael Leonard, but training must be complete and current for all <br /> employees that manage hazardous waste. Employee training records shall include: <br /> 1. the job title for each position at the facility related to hazardous waste management, and the name of each <br /> employee filling each job; <br /> 2. written job description for each position listed above; <br /> 3. written description of the type and amount of both introductory and continuing training that will be given to <br /> each person filing positions listed above; <br /> 4. records that document that the training has been given to and completed by facility personnel. <br /> Training records on current employees shall be kept until closure of the facility. Training records on former <br /> employees shall be kept for at least three years from the date the employee last worked at the facility. Ensure that <br /> employee training is properly documented. Submit complete and current training records to the EHD within 30 days. <br /> This is a minor violation. <br /> 502 CCR 66265.192(x) Failed to comply with new hazardous waste tank system assessment requirements. <br /> Facility does not have a tank assessment for the 1,000 gallon used oil tank. The owner or operator of a hazardous <br /> waste tank shall obtain a written assessment reviewed and certified by an independent, qualified, professional <br /> engineer, registered in California attesting that the system has sufficient structural integrity, is acceptable for the <br /> transferring, storing, and treating of hazardous waste, and that the tanks and containment system are suitably <br /> designed. Immediately have an assessment prepared for the 1,00 gallon used oil tank. Submit a schedule showing <br /> when this will be accomplished to the EHD. <br /> This is a Class I violation. <br /> FA0003769 PR0513643 SCO01 07/31/2015 <br /> EHD 22-02 Rev.09/22/16 Page 5 of 7 Large Quantity Hazardous Waste Generator OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.