My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS_2000-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAGNER
>
200
>
2900 - Site Mitigation Program
>
PR0009002
>
FIELD DOCUMENTS_2000-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 3:11:07 PM
Creation date
6/17/2020 1:43:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
FileName_PostFix
2000-2003
RECORD_ID
PR0009002
PE
2960
FACILITY_ID
FA0004040
FACILITY_NAME
SPX COOLING TECHNOLOGIES INC
STREET_NUMBER
200
Direction
N
STREET_NAME
WAGNER
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
14331007
CURRENT_STATUS
02
SITE_LOCATION
200 N WAGNER AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM NO. R5-200340XXX • 2 <br /> SPX CORPORATION <br /> MARLEY COOLING TOWER COMPANY <br /> SAN JOAQUIN COUNTY <br /> Constituents Units Type of Sample Frequency <br /> Dissolved Oxygen mg/L (ppm) Grab Monthly <br /> Chlorine Residual mg/L (ppm) Grab Monthly <br /> lbs/day <br /> Hardness (as CaCO-.)t mg/L (ppm) Grab Monthly <br /> Total Dissolved Solids mg/L (ppm) Grab Monthly <br /> Total Suspended Solids mg/L (ppm) Grab Monthly <br /> Total ChromiUM2 µg/1 (ppb) Grab Monthly <br /> lbs/day <br /> Hexavalent Chromium' gg/1 (ppb) Grab Monthly <br /> lbs/day <br /> Copper(Total)2 µg/1 (ppb) Grab Monthly <br /> lbs/day <br /> Arsenic (Total)2 µg/I (ppb) Grab Monthly <br /> lbs/day <br /> Iron (Total) gg/l (ppb) Grab Quarterly <br /> Turbidity NTU Grab Monthly <br /> Acute Toxicity4 % Survival Grab Quarterly <br /> Concurrent with metals monitorine. <br /> At a minimum the Discharger shall comply with the Monitoring Requirements for these constituents as outlined in <br /> Section 2.3 and 2.4 of the Policy for Implementation of Toxics Standards for Inland Surface Waters,Enclosed Bays,and <br /> Estuaries of California(SIP),adopted 2 March 2000 by the State Water Resources Control Board. For each priority <br /> pollutant use an analytical method from the SIP,Appendix 4 with a Minimum Level(ML)below all applicable pollutant <br /> criteria. In accordance with Section 2.4.2 of the SIP,the Discharger is to instruct the laboratory analyzing samples for <br /> priority pollutants to establish calibration standards so that the ML is the lowest calibration standard. At no time is the <br /> Discharger to use analytical data derived from extrapolation beyond the lowest point of the calibration curve.Report all <br /> peaks identified by the EPA test methods.- <br /> 3 <br /> ethods:3 Field measurements. <br /> 4 The acute bioassays samples shall be analyzed using EPA/600/4-90/027F,Fourth Edition,or later amendment with Board <br /> staff approval. Temperature and pH shall be recorded at the time of bioassay sample collection. Test species shall be <br /> fathead minnows(Pimephales promelas). <br />
The URL can be used to link to this page
Your browser does not support the video tag.