My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0008213
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
2801
>
2900 - Site Mitigation Program
>
PR0504943
>
ARCHIVED REPORTS_XR0008213
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2020 12:53:26 PM
Creation date
6/18/2020 12:16:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008213
RECORD_ID
PR0504943
PE
2951
FACILITY_ID
FA0004032
FACILITY_NAME
AMERICAN MOULDING & MILLWORK (FRMR)
STREET_NUMBER
2801
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11709001
CURRENT_STATUS
02
SITE_LOCATION
2801 WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
194
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14. Fill "Titration Vessel" approximately one-third full with the HCl <br /> solution. <br /> 15. Turn on oxygen. Set the pressure to 15 psi, and the flow rate to 1.0 <br /> liter per minute. NOTE: 0:)Wgen flow must be started before starch is added. <br /> 16. Raise the "Locking Mechanism Handle" WITHOUT a sample crucible on the <br /> pedestal, and lock in place. NOTE: Make sure there is an airtight contact <br /> between sample platform and combustion chamber by observing a vigorous <br /> bubbling in the "Titration Vessel" chamber. <br /> 17. Add one measure (5 ml) of starch solution. NOTE: If solution in <br /> "Titration Vessel" chamber turns turbid or yellow after starch solution is <br /> added, turn off the instrument following steps 33 through 39 and make NEW <br /> starch solution. <br /> 18. Set "Titrate-Endpoint" switch to "Endpoint. " <br /> 19. After a feu seconds when titrant level in "Iodate Buret" has stopped <br /> falling (Buret reading should be no more than 0.004) the solution in the <br /> "Titration Vessel" chamber should be a deep blue. NOTE: If the solution <br /> is a pale blue or almost black, turn off the instrument following steps 33 <br /> through 39 and make NEW starch solution. <br /> 20. Set "Titrate-Endpoint" switch to middle position and lower "Locking <br /> Mechanism Handle." <br /> 21. Refill "Iodate Buret." <br /> 22. Place sample crucible on pedestal, making sure it is centered, and <br /> carefully raise "Locking Mechanism Handle" and lock in place. <br /> NOTE: Make sure there is an airtight contact between sample platform and <br /> combustion chamber by observing a vigorous bubbling in the "Titration <br /> Vessel" chamber. <br /> 23. Set "Titrate-Endpoint" switch to Titrate, or if it is known that sample <br /> will evolve S02 slowly, set switch at Endpoint. The Endpoint setting acts <br /> as a "Fine Control" allowing buret valve to discriminate smaller increments. <br /> 24. Push RED button on timer to start analysis. <br /> 25. Plate current must go to 400-450 ma for at least 2 minutes during the <br /> analysis; if not, reweigh and rerun sample. <br />} 25. Adjust rheostat to prevent plate current from exceeding 450 ma. <br /> 3 <br /> 27. When buret reading does not change for 2 minutes, and Plate Current <br /> has achieved 400 to 450 ma, it can be assumed that all of the sulfur has <br /> been removed from the sample. If buret reading is still changing when timer <br /> shuts off instrument, set Timer Switch to OFF, which restarts furnace, leave <br /> furnace on until buret is stable for 2 minutes, then turn Timer Switch to ON. <br /> 54 <br /> A <br />
The URL can be used to link to this page
Your browser does not support the video tag.