My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2021 9:17:28 AM
Creation date
6/18/2020 4:14:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231995
PE
2361
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
01
SITE_LOCATION
1403 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GPH = Gallons per hour, Y = Yes, N = No, NA = Not applicable, VPH = Vacuum/Pressure/Hydrostatic, ID = Identification <br />UNDERGROUND STORAGE TANK <br />MONITORING SYSTEM CERTIFICATION FORM <br />XII. LINE LEAK DETECTOR TESTING <br />Check this box if line leak detectors (LLD) are NOT installed. (Do not complete this section.)Y N NAThis section must be completed if LLDs are installed. <br />Was a leak simulated to verify LLD performance? <br />(Check all that apply.)Simulated leak rate verified:3 GPH 0.1 GPH 0.2 GPH <br />Was the testing apparatus properly calibrated? <br />For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? <br />For mechanical LLDs, does the LLD restrict the flow through the pipe when a leak is detected? <br />For electronic LLDs, does the turbine automatically shut off when a leak is detected? <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? <br />For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? <br />Were all LLDs confirmed operational within regulatory requirements? <br />in section XIII how and when these issues were or will be corrected. <br />XIII.COMMENTS <br />XIV. VACUUM / PRESSURE/ HYDROSTATIC MONITORING EQUIPMENT TESTING <br />Check this box if VPH monitoring is NOT used.(Do not complete this section.) <br />This section must be completed if VPH monitoring is used to perform leak detection monitoring. <br />System Type (Mark all that apply.)Vacuum Pressure Hydrostatic <br />Sensor ID Component(s) Monitored by this Sensor Sensor Functionality <br />Test <br />Interstitial Communication <br />Test <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />Pass Fail Pass Fail <br />How was interstitial communication verified?Simulated leak at far ends of the interstitial space. <br />Visual Inspection <br />Other (Describe the method in section XV below.) <br />Gauge <br />Was the vacuum or pressure restored to operating levels in all interstitial spaces?Yes No (Describe the reason in section XV below.) <br />in section XV how and when these issues were or will be corrected. <br />XV. COMMENTS
The URL can be used to link to this page
Your browser does not support the video tag.