My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0012663
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1100
>
2900 - Site Mitigation Program
>
PR0507217
>
ARCHIVED REPORTS_XR0012663
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2020 4:53:26 PM
Creation date
6/23/2020 2:20:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012663
RECORD_ID
PR0507217
PE
2950
FACILITY_ID
FA0007741
FACILITY_NAME
AUTO ZONE INC
STREET_NUMBER
1100
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95202
APN
11733035
CURRENT_STATUS
02
SITE_LOCATION
1100 N WILSON WAY
P_LOCATION
01
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
460
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f ; <br /> ANALYTICAL QUALITY CONTROL <br /> Quality control measurements verify the integrity of the <br /> analytical results, while the goal of all quality control <br /> procedures remains constant, specific quality control <br /> procedures vary from method to method, and to some extent, <br /> with matrix type. Each analyst is responsible for a thorough <br /> understanding of the goal of the Quality Control Program, as <br /> well as how the program is implemented 2n each method. The <br /> analyst is also responsible for the documentation of all <br /> — quality control measurements associated with a particular <br /> method. All documentation is kept in a bound notebook and <br /> securely stored for a minimum of 10 years. <br /> m <br /> c3engral Requirements <br /> Sequoia Analytical adheres to the duality control procedures <br /> set cut in SW-846 Chapter 1, Revisio: 1, 2987 for the <br /> majority of analytical procedures. Saquaia also adheres to <br /> any additional quality control procedures set out in a <br /> particular method. Other method references may include the <br /> California Title 22 Code, 4alifornia AB 1803, Code of Federal <br /> Regulations 40, and Standard Methods, 16th Edition. <br /> Accuracy measurements are performed every 20 samples or once <br /> every analytical batch per matrix type, whichever is fewer. <br /> — An environmental sample of the appropriate matrix for the <br /> analytical batch is spiked with a known quantity of the <br /> artalyte(s) and the % recovery documented (Figure 9) . <br /> pre^ision measurements are performed at the same frequency by <br /> repeating the spike in a field duplicate of the originally <br /> spiked sample. The % deviation between the two s eked <br /> duplicates is documented (Figure 10) . Both the history of <br /> accuracy and the history for precision are charted in the <br /> analysts, Q.C. notebook (Figure 11) . <br /> k .' Acceptance limits for accuracy and precision are based an ±2 <br /> standard deviations from the average of the mostrecent 20 <br /> entries Yor each parameter unless otherwise specified by the <br /> EPA method. A reagent blank is also run at the same <br /> frequency as spikes and duplicates. <br /> Each analyst is responsible for proper instrument <br /> r <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.