My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007874
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1100
>
2900 - Site Mitigation Program
>
PR0507217
>
ARCHIVED REPORTS_XR0007874
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/8/2020 10:09:58 PM
Creation date
6/23/2020 2:52:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007874
RECORD_ID
PR0507217
PE
2950
FACILITY_ID
FA0007741
FACILITY_NAME
AUTO ZONE INC
STREET_NUMBER
1100
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95202
APN
11733035
CURRENT_STATUS
02
SITE_LOCATION
1100 N WILSON WAY
P_LOCATION
01
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Coca-Cola Enterprises - West <br /> USTEC Job No. 90054.03 <br /> When the hydrocarbon contaminated process gas passes through the silica bed and approaches <br /> the heating elements its temperature rapidly increases Complete combustion occurs when the <br /> ignition point is reached in the middle of the oxidizer bed due to the oxygen content of the <br /> process gas. With a sufficient concentration of hydrocarbons in the incoming process gas(about <br /> 200 ppm gasoline), the heat energy is sufficient so that the destruction reaction of the <br /> hydrocarbons is self-sustaining and no additional heat energy is required during the process <br /> operation. <br /> 5.4.2 Fan Motor. and Drive <br /> IThe unit is equipped with a regenerative blower designed for continuous service The blower <br /> system also includes a flow control sampler,drive motor,belts,pulleys,and guards. The blower <br /> and drive parameters are listed below <br /> Flow 600 cfm at 70°F <br /> Vacuum 12" Hg total <br /> Horsepower 40 (electric) <br /> The unit is capable of operation in this installation at 100 200 cfm without a mayor loss of <br /> ' efficiency. <br /> 5.4.3 Heat Transfer Media <br /> The high temperature heat transfer media consists of a single porous bed of silica gravel,sized <br /> ' to provide the most efficient heat recovery while maintaining the optimum pressure drop for the <br /> application <br /> 5.4.4 Bed Casing <br /> The bed casing consists of an all-welded construction stiffened to withstand the forced draft <br /> ' pressure requirements and lateral loads from the heat transfer media <br /> 21 <br /> L-f T <br />
The URL can be used to link to this page
Your browser does not support the video tag.