Unrecorded Facility Well <br /> Coca-Cola Former Distribution Fauldy <br /> 1100 North Wilson Way, Stockton, CA <br /> Project No 54006 02 <br /> Page 2 <br /> well is screened in the shallowest aquifer It is proposed that this unrecorded facility well be <br /> destroyed by backfilling the well with a pressurized, tremied mixture of neat cement and five <br /> percent bentonite grout up to six inches below existing grade After the well backfill has set, <br /> the concrete berm will be removed and the last six inches of the well will be filled with Class <br /> B concrete and finished flush with the existing grade RESNA requests approval of the <br /> destruction method of this unrecorded facility well by SJCPHS-EHD Upon approval of the <br /> destruction method RESNA will obtain required well destruction permits <br /> If you have any questions or comments regarding this matter please contact our office <br /> Respectfully, <br /> RESNA Industries, Inc <br /> Jeanne Homsey, P E <br /> CA Registered Civil Engineer No 47410 <br /> JJH/ggk <br /> Attachment <br /> PC Ann Macdonald, Coca-Cola Enterprises - West <br /> Reginald Prime, Coca-Cola Enterprises, Inc <br /> Wayne Bachman, RESNA Industries, Inc <br /> Joan Tiernan, RESNA Industries, Inc <br /> e W) e <br /> C_'M'00/�w r <br /> 4 �Y <br /> d�11 <br /> REPORTs/LR012693 DRF <br />