My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2494
>
2300 - Underground Storage Tank Program
>
PR0231104
>
COMPLIANCE INFO_2004-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2023 2:08:21 PM
Creation date
6/23/2020 6:37:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2009
RECORD_ID
PR0231104
PE
2351
FACILITY_ID
FA0003863
FACILITY_NAME
SOHAL #3
STREET_NUMBER
2494
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15328008
CURRENT_STATUS
01
SITE_LOCATION
2494 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\2494\PR0231104\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
496
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 324.02 <br /> Complete the follov�W g checklist: <br /> x Yes No* Is the audible alarm operational? <br /> x Yes No* Is the visual alarm operational? <br /> x Yes No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> x Yes No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> DroDer oDe iga? <br /> x Yes No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> WA <br /> x Yes No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system <br /> N/A detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate positive shut-down? (Check all Not apply) <br /> x Sumprrrench Sensors; x Dispenser Containment Sensors, Did you confirm positive shut-down due to leaks and sensor <br /> _Lailuretdisconnectign? x Ye g; No. <br /> x Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(.e.no mechanical overfill prevention <br /> N/A valve is installed),is the overfill warning alan-n visible and audible at the tank fill point(s)and operating properly? If so,at what percent <br /> I- of tank caDacit does the alarm trianer? % <br /> Yes* No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all reelacement its in Section E,below. <br /> x Yes. No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; xWater. If <br /> _12ELdescribe causes in Section E,below. <br /> x Yes No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> x Yes No* Is all monitoring equipment operational Eer manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Found small amount of water in 87 Fill and 91 Fill. Removed Water. <br /> Monitoring System Certification Page 2 of 4 12107 <br /> 2 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.