Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑Repair Inspection 2136 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181319 10/5/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> KNIFE RIVER CONSTRUCTION <br /> Business Site Address City ZIP Code <br /> 655 W CLAY ST. TSTOCKTON, CA 95206 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Felix Ramirez (209) 744-0112 <br /> Contractor I Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 08-1740 Ex. 03/31/2020 8883080-UT 11/8/2018 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> FF- EBW , Phil-Tite & EVR Phase 1 1009883708 EX 11-16-18 OPW 104-634 Ex 3-14-2020 <br /> Emco 3147 Ex. 9-21-20 VR: B34976 ATG: 7/7/20 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMAID161V <br /> Inspection Method ®Manufacturer Guidelines(Specify): <br /> Used: REMOVED DROP TUBES OCT 3 1 2018 <br /> ❑Industry Code or Engineering Standard(Specify): <br /> 1 :�LI <br /> ❑Engineered Method(Specify): 1)1 `y,®,ZT '[ 1 <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages <br /> TANK ID: (By tank number,stored product,etc.) 87 DIE <br /> What is the tank inside diameter?(Inches) 92 119 <br /> Is the fill piping secondarily contained? ❑Yes ®No ❑Yes ®No ❑Yes ❑No ❑Yes ❑No <br /> Is the vent piping secondarily contained? ®Yes ❑No ®Yes ❑No ❑Yes ❑No ❑Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) oPw EBW <br /> 61-50 <br /> What is the overfill prevention equipment response ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? ❑x Restricts Flow 0 Restricts Flow ❑Restricts Flow ❑Restricts Flow <br /> (Check all that apply.) <br /> ❑AN Alarm ❑AN Alarm ❑AIV Alarm ❑AIV Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes 0 No ❑Yes [E No ❑Yes ❑No ❑Yes ❑No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 85 108 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 93% 92% <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ®Pass ❑Fail 11 ❑x Pass ❑Fail J1 ❑Pass ❑Fail ❑Pass ❑Fail <br /> V. COMMENTS <br /> Any items marked"Fail'must be explained in this section. Any additional comments may also be provided here. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature — <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AIV=Audible and Visual <br />