Laserfiche WebLink
, ,1. CIC Three complete sets of p (include manufacturer's specification she or proposed equipment to be installed). <br /> 2. « Plans drawn to scale in non-erasable print. <br /> 3. Plot plan to show location of tanks and all associated piping. <br /> 4. Striker plates or drop tube-mounted bottom protectors illustrated below all accessible openings. <br /> 5. CK Tank cross-sectional diagram. <br /> 6. OC• Detail of tank, associated piping, excavation and cover. <br /> 7. 0� Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Chapter 16, <br /> Article 3, Section 2631 (b) & 26351 <br /> 8. �_ verification of product compatibility with the tank(s), piping, monitoring <br /> device(s), epoxy or silicone glues, etc. <br /> 9. Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. <br /> 10. At the installation site, prior to installation, a tightness test shall be performed on both primary (1°) and <br /> secondary (2°) containment systems before covering. [Section 2635 (a) (3) & (4)] <br /> 11. Tank integrity test required upon completion of installation with tank in operating condition. Test results to be <br /> submitted directly to PHS-EHO from the testing company/ or owner of facility. [Health & Safety Code, Division 20, <br /> Chapter 6.7, Section 25291 (h)] <br /> 12. TANK COMPOSITION <br /> TANK # # ®, #®Z # # # <br /> CAPACITY 101 10,000 <br /> MANUFACTURER coni2invftnt qMUM <br /> COMPOSITION -'Jr-�J� <br /> MODEL 5T E310 J5T NO <br /> PRODUCT 74q. UnI• prem. URi. <br /> CORROSION PROTECTION HU PIS NDPp_ <br /> U.L. LISTED Yd_12 <br /> COMPATIBILITY WITH 100% <br /> METHANOL <br /> 13. TANK( TO BE INSTALLED <br /> A Steel-clad with fiberglass reinforced plastic coatings, composites, or equivalent non-metallic exterior <br /> coatings or coverings. <br /> ® (1) Tested at the installation site using an electric resistance holiday detector. <br /> (2) vacuum applied to interstitial space. <br /> a. Fiberglass <br /> (1) Installation instructions require an air test and soap bubble test prior to installation. <br /> — (2) Vacuum applied to interstitial space. <br /> (3) Hydrostatic annular (primary tank pressure test). <br /> C. Non-clad steel tank [Section 2635 (a) (2) (A)3 <br /> (1) Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br /> etc.). <br /> (2) Field installed cathodic protection systems designed and certified as adequate by a <br /> corrosion specialist. <br /> (3) Imrpressed current systems to be inspected no less than every 60 days. <br /> 5 <br />