My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_1998-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 9:51:39 AM
Creation date
6/23/2020 6:40:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2002
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_1998-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
341
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEW UST INSTALLATION INSPECTION RECORD <br />FACILITY, NAME. <br />ADDRESS: <br />FACILITY ID# <br />7. SECONDARY PIPING CONTAINMENT TEST PSI: NRS/MIN: OTHER: (CCR 2636 (e)) <br />TANK# UL# <br />TANK MODEL/MATERIAL: <br />CAPACITY: <br />8. LAKE TEST ON ALL SUMPS (24 HR. MINIMUM) NRS: (CCR 2635 (a) (4)) <br />PRODUCT: <br />R.E.H.S: <br />A <br />I <br />10. OVERSPILL PERFORMANCE TEST (CCR 2635 (b) (1) (C)) <br />P <br />N <br />ALL TANKS TO BE INSTALLED AND <br />TESTED IN ACCORDANCE <br />P <br />I <br />20. TANK INTEGRITY TEST (PASSING HARD COPY) (CCR 2635 (a) (5)) <br />WITH MANUFACTURER WRITTEN <br />SPECIFICATIONS <br />R <br />T <br />22. "C" FORM COMPLETED AND SUBMITTED (CCR 2635 (d)) <br />0 <br />I <br />23. MONITORING METHOD FOR ALL TANKS AND PIPINGAPPROVED (CCR 2630-2636) <br />V <br />A <br />E <br />L <br />D <br />S <br />ITEM OR EQUIPMENT INSPECTED <br />DATE <br />1. <br />UST PLANS SUBMITTED/ FEES PAID <br />(H+S CODE 25287) <br />2. <br />UST INSTALLATION PLANS APPROVED <br />INITIAL INSPECTIONS <br />3. <br />INSPECTION AND TEST OF SECONDARY CONTAINMENT: <br />HOLIDAY: <br />VACUUM: SOAP: PSI: HRS/MIN: <br />BRINE(LIQUID ANNULAR): OTHER: <br />4. <br />PRIMARY TANK TEST: PSI: <br />HRS/MIN: <br />5. <br />TANK APPROPRIATELY PLACED WITH APPROVED BACKFILL <br />(API/PEI) <br />PIPING INSPECTIONS <br />FINAL INSPECTION <br />6. PRIMARY PIPING TEST (MINIMUM 40 PSI/30 MIN) (CCR 2636 (e)) <br />7. SECONDARY PIPING CONTAINMENT TEST PSI: NRS/MIN: OTHER: (CCR 2636 (e)) <br />8. LAKE TEST ON ALL SUMPS (24 HR. MINIMUM) NRS: (CCR 2635 (a) (4)) <br />9. UNUSED TANK OPENINGS SEALED AND CORROSION PROTECTED PEI <br />10. OVERSPILL PERFORMANCE TEST (CCR 2635 (b) (1) (C)) <br />11. ALL PIPING AND FITTINGS CORROSION PROTECTED (CCR 2636 (b)) <br />12. PIPING SLOPES TO COLLECTION SUMP (CCR 2636 (c)(1)) <br />FINAL INSPECTION <br />COMMENTS:— <br />EH23-006 9/95 <br />10 <br />13. PERFORMANCE TEST FOR "ALL" MONITORING PROBES (CCR 2632 (c) (2)) <br />14. PERFORMANCE TEST OF CONTINUOUS MONITORING SYSTEM (PANEL) (CCR 2632 (c) (2)) <br />15. PERFORMANCE TEST OF LINE LEAK DETECTION (CCR 2643 (c) (1)) <br />16. PERFORMANCE TEST OF AUTOMATIC PUMP SYSTEM SHUT-OFF (CCR 2636 (g)) <br />17. BALL FLOAT VALVES INSTALLED <br />18. OVERFILL PROTECTION INSTALLED/APPROVED (CCR 2635 (b) (2)) <br />19. TANK ACCESS PORTS BROUGHT TO GRADE (LOCKED AND WATERTIGHT). API <br />20. TANK INTEGRITY TEST (PASSING HARD COPY) (CCR 2635 (a) (5)) <br />21. MONITORING PLAN, RESPONSE PLAN AND LOG BOOK ON SITE (CCR 2632 (d)) <br />22. "C" FORM COMPLETED AND SUBMITTED (CCR 2635 (d)) <br />23. MONITORING METHOD FOR ALL TANKS AND PIPINGAPPROVED (CCR 2630-2636) <br />24. ALL CONDITIONS MET; FACILITY PERMIT ISSUED (H+S CODE 25284) <br />COMMENTS:— <br />EH23-006 9/95 <br />10 <br />