My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 11:20:58 AM
Creation date
6/23/2020 6:41:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Is Page 5. <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC)TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer F-1 Industry Standard Professional Engineer <br /> 0 Other (Specify) <br /> Test Method Used: FI Pressure F-1 Vacuum x❑ Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used: vp1t Equipment Resolution: inches <br /> UDC# <br /> 1/2 UDC# 3/4 UDC# UDC# <br /> UDC Manufacturer: environ environ <br /> UDC Material: hpde hpde <br /> UDC Depth: 29" 2 9 <br /> Height from UDC Top to Top of 11 1111 <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 811 <br /> 811 <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good <br /> Portion of UDC Tested: 1 1311 1311 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both lYes❑No❑N Yes�Na❑N Yes�N�N Yes❑No[]N <br /> product and water)?* <br /> Turbine shutdown response time: 2-5 s e c 2-5 s e c <br /> Is system programmed for fail-safe � ❑ ❑ ❑ ❑ ❑ ❑ <br /> shutdown?* Yes N N X Yes N N Yes N N Yes No <br /> Was fail-safe verified to be ❑ � ❑ � ❑ � ❑ <br /> operational?* X Yes N N X❑Yes N N X❑Yes N N Yes No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5min 5 min <br /> test: <br /> Test Start Time: 10:45 11:45 <br /> Initial Reading(RI): 0 0 <br /> Test End Time: 11:00 12:00 <br /> Final Reading(RF): -.00011, -.0003" <br /> Test Duration: 15min 15min <br /> Change in Reading(R F-RI ): -.00011, -.0003" <br /> Pass/Fail Threshold or Criteria: +- .00211 +-.00211 <br /> Was sensor removed for testing? aYes❑No❑NA MYesE]N NA❑Yes❑NoE]NA[]Yes[]No� <br /> Was sensor properly replaced and ❑ ❑ <br /> verified functional after testing? Ye N NA Ye N NA Ye N NA Yes N <br /> Comments- (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer to-any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />