My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2057
>
2300 - Underground Storage Tank Program
>
PR0231083
>
COMPLIANCE INFO_2000-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 3:49:03 PM
Creation date
6/23/2020 6:41:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2011
RECORD_ID
PR0231083
PE
2361
FACILITY_ID
FA0003735
FACILITY_NAME
QUICK N EASY MART
STREET_NUMBER
2057
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16515309
CURRENT_STATUS
01
SITE_LOCATION
2057 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\EL DORADO\2057\PR0231083\PERMANENT INJUNCTION & FINAL JUDGMENT 10-19-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />SWRCB, .I anuary 2002 <br />Page of <br />' Secondaiy containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: <br />❑ Tank Manufacturer rAndustry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure @'Vacuum <br />❑ Other (Spec) <br />❑ Hydrostatic <br />Test Equipment Used: VACUUM <br />Is Tank E:tempt From Testing?' <br />Tank # 97/91 Tank # <br />❑Yes 5'No ❑ Yes ❑ No <br />Equipment Resolution: "hg <br />Tank # Tank # <br />❑ Yes ❑ No ❑ Yes ❑ No <br />Tank Capacity: <br />20K <br />Tank Material: <br />FIBERGLASS <br />Tank Mar ufacturer: <br />WESTERN FIB <br />Product S-tored: <br />FUEL <br />Wait time: between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start: Time: <br />0924 <br />Initial Reeding (Ri): <br />10" <br />Test End Time: <br />1024 <br />Final Reeding (RF): <br />10" <br />Test Dur, -lion: <br />1 HR <br />Change in Reading (RF -RI): <br />0 <br />Pass/Fail Threshold or Criteria: <br />2" <br />Test ReYalt� <br />fti"'Pas§ ❑ Fall ❑ Pass 0 Fail <br />❑ Pass ❑ Fail ❑ Pass ❑ Fair <br />Was sensor removed for testing? <br />VVes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was senss.)r properly replaced and <br />verified ff mctional after testin ?� <br />❑ No ❑ NA ❑Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' Secondaiy containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />
The URL can be used to link to this page
Your browser does not support the video tag.