Laserfiche WebLink
D. Results of Testing/Servicing <br />w i <br />Software Version Installed: <br />Complete the following checklist: r <br />Yes ❑ No* <br />Is the audible alarm operational? <br />Yes ❑ No* <br />Is the visual alarm operational? <br />Yes ❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Yes D No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />Cl Yes ❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />N/A <br />operational? <br />Yes ❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) d Sump/Trench Sensors; Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? Yes; ❑ No. <br />❑ Yes ❑ No* <br />For tank systems that utilize the monitoring system as the primary tank ove ill warning device (i.e, no <br />N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity=does the: alarm trigger? % <br />❑ Yes*No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />311 <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />Cl Yes* No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that appl}) <br />❑ Product; ❑ Water. If yes, describe causes. in Section E, below. <br />Yes ❑ No* <br />Was monitoring system set-up reviewed to ensure proper settings?. Attach set up reports, if applicable <br />Yes I ❑ No* I <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />