My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2285
>
2300 - Underground Storage Tank Program
>
PR0231111
>
COMPLIANCE INFO_2000-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:24:50 AM
Creation date
6/23/2020 6:42:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2005
RECORD_ID
PR0231111
PE
2361
FACILITY_ID
FA0001659
FACILITY_NAME
QUIK STOP MARKET #7039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
141-214-03
CURRENT_STATUS
01
SITE_LOCATION
2285 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231111_2285 E FREMONT_2000-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> For'Use By All Jurisdictions Within the State of California <br /> Awhority Cited: Chapter o.7, Health and Safer),Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared <br /> for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br /> days of test date. <br /> A. General Informatioll <br /> Facility Name: Q t cw`� Bldg.No.: <br /> Site Address: �� F,• F��V�OIr1 &yf City: 1"1 Zip: 9�S3P�,S <br /> Facility Contact Person: ©wy%er Contact Phone No.: 464—(COT <br /> Mike/Model of Monitoring System: colyborcc _ FYY%L Date of Testing/Servicing: <br /> B. Inventory of Equipment Tested/Certified <br /> Check the&ppropristt boxes to indicate specific.equipmevi inspected/serviced: <br /> Tank ID: Tank ID: <br /> dG In-Tank Gauging Probe. Model: O In-Tank Gauging Probe. Model: <br /> 11 Annular Space or Vault Sensor_ Model: ❑ Annular Space or Vault Sensor. Model: <br /> M Piping Sump/Trench Sensor(s). Model: O Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s)`. Model: <br /> MkM Mechanical Line Leak Detector. Mode]: ��o bei El Mechanical Line Leak Detector. Model: <br /> O Electronic Line Leak Detector. Model: O Electronic Line.Leak Detector. Model: <br /> I�Tank Overfill/High-Level Sensor. Mode]: Chp M/ O Tank Overfill/High-Level Sensor. Model: <br /> O Other(specify equipment type and model in Section E on Page 2). O Other(specify equipment type and model in Section E on Pae 2). <br /> Tank ID- Tank ID: <br /> Ok In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> Annular Space or Vault.knsor. Mode]: ❑ Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Mode]: O Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> (�t Mechanical Line Leak Detector. Model: V—. Q CL_ O Mechanical Line Leak Detector. Mode]: <br /> ❑ Electronic Line Leak Detector. Model: O Electronic Line Leak Detector. Model: <br /> V Tank Overfill/Nigh-Level Sensor. Model: nV►v✓ O Tank Overfill/High-Leve]Sensor. Model: <br /> ❑ Other(s ifv ecui ment type and model in Section Eon Pa e 2). O Other(sREcify equipment type and model in Section E on Page 2). <br /> Dispenser TD: IfCk. Dispenser TD: <br /> Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). ❑ Shear Valve(s). <br /> O Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser TD: Dispenser TD: <br /> Dispenser Containment Sensor(s). Model: O Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). O Shear Valve(s). <br /> O <br /> Dispenser Containment Float(s)and Chain(s). O Dispenser Containment Float(s)and Chain(s). <br /> Dispenser TD: Dispenser TD: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> O Shear Valve(s).' ❑ Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). O Dispenser Containment Float(s)and Chain(s): <br /> •]f the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. CertifiCation -I certify that the equipment identified in this document was in spected/ser•viced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e-g. manufacturers' checklist) necessary to verify that this information is <br /> correct.and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports;l have also <br /> attached a copy of the re ori:(check all that apply): �i System set-up farm hist ry rep rt / <br /> Technician Name(print): Rrinn'e trtiC� Signature: �ar <br /> Certification No.: License.No.: 0,39 7 1 <br /> Testing Company Name: �Y Ay1� f!VtV%ro�#lpJAL Phone Noj '%%2 ) `DC.- r76 6* <br /> Site Address: ea ���o� V� Date of T estjng/Servicing: % �I <br /> Page I of 3 03/01 <br /> MonitorinE Svstem Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.