My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2285
>
2300 - Underground Storage Tank Program
>
PR0231111
>
COMPLIANCE INFO_2006-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 9:09:52 AM
Creation date
6/23/2020 6:43:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2013
RECORD_ID
PR0231111
PE
2361
FACILITY_ID
FA0001659
FACILITY_NAME
QUIK STOP MARKET #7039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
141-214-03
CURRENT_STATUS
01
SITE_LOCATION
2285 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231111_2285 E FREMONT_2006-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OCT -15-2007 MOM 10:36 AM QUI STOP MARKETS FAX NO. 51 571544 P. 06 <br />SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMNT <br />UNDERGROUND STORAGE TANK <br />MONITORING PL. — PAGE 2 <br />♦ is DISPENS E R M0NITO R 1 N O <br />MONITORING OF AREAS BENEAT i DISPENSF..R(S) IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) <br />1. CONTINUOUS EL>:MOxtC MONITORING OF UNDER DISPENSER CONTAINMENT (UDC) � <br />MODEL M AMC t 604 -350 equivalent) <br />PANEL MANUFACTURER Vender Root Gilbarco HrandcA M11. MODEL #(S): 0848480-001 <br />LMC SENSOR MANUFACTURER Veeder Root GitbareD Branded a YES [Ib. NO MSs' <br />WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? Wa. YES ❑ b. NO MS6• <br />WILL A Udo LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? gea. yFS [3b. NO <br />WILL FAILURFJD1SCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN?tIQ <br />❑ 2. MECHANICAL ASSEMBLY (c.g., FLOAT AND CHAIN ASSEMBLY) IN UDC TRIPS SHEAR s MODEL #(S)'.ALVE IN CASE OF LEAK Msv, <br />ASSEMBLY MANUFACTURER M60. <br />❑ 3.VISUALMONITORING DONE: ❑ a. DAILY ❑ b. WEEKLY 6sm-r6Pt7fOY°n <br />❑ 4. NO DISPENSERS M611 <br />❑ 99, OTHER (Specify) <br />YIX. ENHANCED LEAK DETlECTI[ON MTa <br />❑ 1. W& HAVE BEEN NOTIFIED $Y THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK <br />DETECTION (ELD) FOR THE UST(S) COVEl2B1} BY THIS PLAN- PER 23 CCR §2644.1, ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br />♦ Baa. ssocaa�,.... •'®' MBO. <br />REFS CE IDOCUMFNT3 MAINTAINED AT FACILITY (Chock all that applY) <br />1. THIS UNDERGROUND STORAGE TANK MONITORING PLAN (R@qulred) <br />2. 1>C! OPERATDIG MANUALS FOR ELECTRONIC MONL] t)RNG EQUIPMENT uiredj <br />3. THE FACILITY'S BEST MANAGEMENT PRACTICES (Required ss of 1./0112605) <br />4. ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5. ® CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />6. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS -MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION" <br />7. SWRCB PUBLICATION:•• WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS"� <br />99. ❑ OTHER (SpecifY) access those documents when <br />Pcrsormei with UST mWitoring responsibilities are familiar with all of the above d� >cop r, dminisUnd by the internationalCod Council OCC)- <br />Operator who has passed theerator "am <br />By January 1, 2005 this facility will have a"Designated US' operator- will train facility emPI0y= in the proper operation and maintenance of 1110 UST systems. <br />January 1. 2005, and annoallY thereafter, the "Dc6igndU <br />This training will include, but is not limited to, the following: <br />D Operation of the UST systems in a manner consistent with the facility's bat management Practico6. <br />D The facility employee's role with regard to the leak detection ext ip t <br />D The facility employee's Tote with regard to spills and ovc rfllls. <br />➢ Whom to contact for amSencies and leak dctccttat Atrtrti. <br />For facility employees hired on or after Yanuaty 1, 2005, the initial training will be conducted within 30 days of the date of hire- <br />N, <br />ire•N, commENT&ADwTIONAL INFODU ATTr1N <br />Mss. <br />Please iiia this scctim to include any additional UST system monitoring -related' (®.g . additional information required W Yourcta <br />Il agency): <br />Overfill prevention (or protection) is accomplished by the following two (2) methods: <br />1) Mechanical overfill valves (OPW 61SO) installed in drop tubes, <br />2) All service penetrations to tho primary containment arc <br />contained within sump. including the fill and vapor return- <br />2) <br />OF 1,11/05,THE "DESIGNATED UST OPERATOR." IDENTIFIED IN SECTION III OF n CURRENT UST OPERATING P <br />FACILITY ND MAJNTAINING LEAK DETECTION <br />FO O FRED BY THIS PIAN, AND W�AUTHORITY <br />F-RFO AND DOCUMENT MINIMFOR PERFORMING THS UM MONTHLY VISUAAL INSPECTIG AC71VIMON <br />SOF THE FACILITY S <br />EQUIPMENT - D -- . _......, .., ti. -^0 a 7.71 CA.\ <br />i <br />OWNER/OPERATOR NAM I- (print): <br />Mike Karvelot, for Quik Stop Markets, Inc• <br />OWNEWOPORATOR TITLE: <br />Director of FuViron=11tal Affairs <br />C3 Approved With Conditions El Disapprove! <br />(Agency Use Only) This plan has been reviewed and: Q Approved <br />Date: <br />Local Agency Signature: <br />Comments/Spe:ial Conditions: <br />07/23/03 <br />SJCEt1" (01/03) - 314 <br />
The URL can be used to link to this page
Your browser does not support the video tag.