My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 3:02:45 PM
Creation date
6/23/2020 6:43:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_2011-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Valero 3641 Facility 1210 E Hammer Lane, Stockton Inspection Jun 21, 2012 <br />Name: Address: Date: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR -Notice to Comply) <br />Routine and Monitoring System Certification UST inspection <br />Spill container testing was not done today - schedule the test prior to end of July and notify the San <br />Joaquin County Environmental Health Department (EHD) of the test time and date. <br />117. The 91 product tank annular liquid sensor was replaced on December 23, 2011 according to <br />facility records and a permit was not obtained from the EHD. Emergency repairs relating to UST system <br />monitoring and release detection may be performed by a properly licensed, trained, and certified <br />contractor pursuant to the EHD's policy and a permit obtained within one business day from the EHD. <br />All other repairs must have a permit submitted to and approved by the EHD prior to beginning work. <br />Immediately obtain a permit from the EHD for the 91 tank annular sensor replacement. A "Failure to <br />Obtain a Permit" penalty applies. A $750 charge applies: $375 permit fee + $375 penalty. <br />305. The dispenser 1/2 sump Bravo float and chain (middle location) failed to stop the flow of product at <br />the dispenser when tested. The float was cracked and was not air tight. All monitoring equipment shall <br />be maintained to activate an audible and visual alarm or stop the flow of product at the dispenser when it <br />detects a leak. Correct immediately by having a properly licensed, trained, and certified contractor <br />replace the failed component with a functional component (LG 113-x listed, if applicable) and obtain a <br />permit within one business day from the EHD. If the failed component can't be replaced immediately, <br />there is a possibility that the associated UST system may be red tagged to prevent fuel inputs. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD 23-02/ Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.