My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 3:02:45 PM
Creation date
6/23/2020 6:43:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_2011-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. Fill Riser Containment Sump Testing <br />Test Method Developed By: El Tank Manufacturer <br />Test Method Used: El Pressure <br />Test Equipment Used: Incon TS STS Leak Detector <br />Industry Standard El Professional Engineer <br />El Vacuum Hydrostatic <br />Equipment Resolution: ±0.002 <br />Comments: <br />6 of 7 <br />[Fill Sump# 87 <br />Fill Sump# 89 <br />Fill SUMP# 91 <br />Fill Sump # <br />Sump Diameter: <br />48" <br />48" <br />1 48" <br />Sump Depth: <br />45" <br />44" <br />— <br />45" <br />Height from Tank Top to Top of <br />Highest <br />Highest Piping Penetration: <br />Height from Tank Top to <br />0 <br />0 <br />16" <br />17" <br />16" <br />Lowest Electrical Penetration: <br />Condition of sump to <br />prior <br />testing: <br />Ok <br />Ok <br />Ok <br />Portion of Sump Tested: <br />4" <br />4" <br />4" <br />Sump Material: <br />fiberglass <br />fiberglass <br />fiberglass <br />I Wait time: <br />15 min <br />15 min <br />15 min <br />Test Start Time: <br />3:33 <br />3:33 <br />3:33 <br />Initial Reading: <br />1.9061 <br />1.6006 <br />0.1064 <br />Test End Time: <br />3:48 <br />3:48 <br />3:48 <br />-J <br />1.6021 <br />0.1076 <br />Final Reading: 1.9067 <br />Test Duration (hh:mm): <br />00:15 <br />00:15 <br />i <br />00:15 <br />00:00 <br />i Change in Reading: <br />0.0006 <br />0.0015 <br />0.0012 <br />0.0000 <br />Pass/Fail Threshold or Criteria: <br />±0.002 <br />±0.002 <br />±0.002 <br />±0.002 <br />-7-77-, <br />A w <br />T <br />Is there a sensor in the sump? <br />Yes <br />Yes <br />Yes <br />Does the sensor alarm when <br />either product or water is <br />j detected? <br />Yes <br />Yes <br />Yes <br />Was sensor removed for <br />testing? <br />(0 Yes 0 No 0 <br />NA (0 Yes 0 No <br />0 NA <br />(0 Yes 0 No <br />0 Yes 0 No 0 NA <br />Was sensor properly replaced <br />and verified functional after 1 <br />Yes 0 No 0 <br />NA Yes 0 No <br />0 NA <br />(0 Yes 0 No 0 N <br />0 Yes 0 No 0 NA <br />_testing? <br />Comments: <br />6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.