Laserfiche WebLink
11 <br />C <br />7. UDC Testing <br />Test Method Developed By: ❑ Tank Manufacturer FX1 Industry Standard <br />Test Method Used: ❑ Pressure <br />Test Equipment Used: Incon TS STS Leak Detector <br />❑ vacuum <br />❑ Professional Engineer <br />❑x Hydrostatic <br />Equipment Resolution: ±0.002 <br />5 of 7 <br />UDC # <br />1-2 <br />UDC # <br />3-4 <br />UDC # <br />5-6 <br />UDC # 7-8 <br />UDC Manufacturer: <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />UDC Material: <br />UDC Depth: <br />Steel <br />g" <br />Steel <br />91, <br />Steel <br />91, <br />Steel <br />91, <br />Height from UDC Bottom to <br />Top of Highest Piping <br />! <br />0 <br />10 <br />0 <br />0 <br />Penetration: <br />Height from UDC Bottom to <br />0 <br />0 <br />0 <br />0 <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />testing: <br />Ok <br />Ok <br />Ok <br />Ok <br />Portion of UDC Tested <br />4' <br />4" <br />4" <br />4" <br />Does turbine shut down when <br />0 Yes <br />0 No <br />UO NA 0 Yes <br />0 No <br />(ON A <br />0 Yes <br />0 No <br />(0 NA <br />0 Yes 0 No (0 NA <br />UDC sensor detects liquid? <br />Turbine shutdown response <br />N/A <br />N/A <br />N/A <br />N/A <br />time: <br />Is system programmed for fail- <br />0 Yes <br />0 No <br />(0 NA 0 Yes <br />0 No <br />(0 NA <br />0 Yes <br />0 No <br />® NA <br />0 Yes 0 No (0 NA <br />safe shutdown? <br />; <br />Was fail-safe verified to be <br />- <br />--------� <br />—.--- - <br />I operational? <br />0 Yes <br />0 No <br />0 NA 0 Yes <br />0 No <br />NA <br />0 Yes <br />0 No <br />NA <br />0 Yes 0 No 0 NA <br />Wait time: <br />15 min <br />-4--:2-8- <br />15 min <br />i <br />15 min <br />15 min <br />i <br />Test Start Time <br />28 <br />4:02 <br />5:04 <br />5:04 <br />Initial Reading: <br />0.7621 <br />0.5295 <br />0.5738 <br />1.9989 <br />rTest End Time: <br />4 43 <br />4:18 <br />5:19 <br />5:19 <br />Final Reading: <br />0.7633 <br />0.5278 <br />! <br />0.5737 <br />1 <br />1.9984 <br />Test Duration (hh:mm) : <br />00:15 <br />00:16 <br />00:15 <br />00:15 <br />Change in Reading: <br />0.0012 <br />-0.0017 <br />-0.0001 <br />-0.0005 _ <br />Pass/Fail Threshold or <br />Criteria. <br />_ 0 002 <br />- - - <br />+0.002 <br />- <br />±0.002 <br />+0.002 <br />±0.002 <br />T+ stRe�iilt Pis"S fall Q. PassWas Fall <br />removed for <br />PsS, U Fall <br />1 �� # i� <br />- 0 Yes <br />0 No <br />(6 NA 0 Yes <br />0 No <br />NA L <br />0 Yes <br />0 No <br />NA <br />0 Yes 0 No NA- <br />Iftesting?nsor <br />- <br />- <br />—� <br />Was sensor properly replaced <br />and verified functional after <br />0 Yes <br />0 No <br />0 Yes <br />NA <br />0 No <br />0 NA <br />0 Yes <br />0 No <br />(0 NA <br />0 Yes 0 No NA <br />testing? <br />; <br />5 of 7 <br />