Laserfiche WebLink
°P S A NA OA N Environm ntal Health Department <br /> Gil ' COUNTY Linda Turkatte, RENS, Director <br /> Greotness grows here. Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, REHS, RDI <br /> Rodney Estrada, REHS <br /> Willy Ng, REHS <br /> Muniappa Naidu, REHS <br /> December 5, 2017 <br /> MARTY WEITHMAN <br /> SERVICE STATION SYSTEMS INC FILE <br /> 680 QUINN AVE <br /> SAN JOSE, CA 95112 <br /> Re: TIWANA GAS & FOOD AMENDED - SR0077395 <br /> 1210 E HAMMER LN <br /> STOCKTON, CA 95210 <br /> The San Joaquin County Environmental Health Department (EHD) has completed review of the <br /> amended application for a permit to replace the damaged ICON conduit boot and 87-product Bravo <br /> hub in the under dispenser containment (UDC) 7/8 on the underground storage tank (UST) system at <br /> the above noted address. Please note that the service requestor has elected to replace the 87-product <br /> Bravo hub in UDC 7/8 instead of waiting for the manufacture's approval to modify the Bravo hub due to <br /> time constraints. The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Elianna Florido at (209) 468-0343 to arrange the following appointments (a 48-hour <br /> notice is required for inspection appointments). Please be aware that inspection for emergency <br /> work must be scheduled within five days of permit approval. <br /> • Primary piping soap test: One hour pneumatic pressure test for the 87-octane piping, at <br /> 110% of operating pressure, or 40 psi, whichever is greater. <br /> • Secondary piping soap test: One hour pressure test of the 87-octane piping, per <br /> manufacturer's guidelines. If there are no manufacture's guidelines, test shall be <br /> performed using an applicable method specified in an industry code or engineering <br /> standard. <br /> • Secondary piping test for all product piping in the vicinity of UDC-7/8 (where excavation <br /> took place): One hour pressure test for all piping, per manufacturer's guidelines. If there <br /> are no manufacture's guidelines, test shall be performed using an applicable method <br /> specified in an industry code or engineering standard. <br /> • 24-hour hydrostatic test (or equivalent) on UDC-7/8 sump after concrete has been <br /> poured. <br /> Please be aware that the facility cannot operate the 87-product UST system prior to the <br /> EHD inspection and approval. <br /> 4. If concrete will be broken near the tank, a secondary containment test must be performed on <br /> the affected USTs once concrete is poured in accordance with the manufacture's guidelines. <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />