T 4: D I ESEL <br />2.0 <br />PRODUCT CODE <br />4 <br />THERMAL COEFF •:'.000450 <br />10,369 <br />TANK DIAMETER <br />120.00 <br />TANI' PROFILE <br />4 PTS <br />FULL VOL <br />10369 <br />90.0 INCH VOL <br />8676 <br />60.0 INCH VOL <br />5377 <br />30.0 INCH VOL <br />2007 <br />FLOAT S'IZE: 4.0 IN. 8496 <br />WATER WARNING <br />2.0 <br />HIGH WATER LIMIT: <br />'.5 <br />Pli:X OR LABEL VOL: <br />10,369 <br />OVERFILL LIMIT <br />901, <br />9332 <br />HIGH PRODUCT <br />95% <br />9850 <br />DELIVERY LIMIT <br />20% <br />2073 <br />LOW PRODUCT <br />500 <br />LEAK ALARM LIMIT: <br />50 <br />SUDDEN LOSS LIMIT: <br />50 <br />TANK TILT <br />0.85 <br />MANIFOLDED TANKS <br />T#: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 10% <br />1036 <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BR&il':OFF <br />DELIVERY DELAY : 2 MIN <br />LEAK TEST METHOD <br />- - - - - - - - -- - - - <br />TEST O1'4 DATE : ALL TANK <br />JAN 1, 1996 <br />START TIME. UIS AB;LED;.l <br />DURATION 2 HOURS <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LI(JlJID SENSOR SETUP <br />- - - - - - - - - - - - <br />L I : 91 SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SU11P <br />L 2:91 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 3:89 SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 4:89 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 5:87 SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 6:87 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 7:DIESEL SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 8:DIESEL ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />OUTPUT RELAY SETUP <br />R I :91 RELAY <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />N-TA(ql;,.' ALAPM,. <br />T I:LEAy ALARM <br />T I :HIGH WATER ALARM <br />T I :LOW PRODUCT ALARM <br />LIOUID SENSORHLPIS <br />L I:FUEL ALARPI <br />L I :SENsoR OUT ALARM <br />L I :SHORT ALARM <br />R 2:89 RELAY <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />I N -TANK' ALARMS <br />T 2: LEAI-'.'. ALARM <br />T 2:HIGH WATER ALARM <br />T 2:LOIIl PRODUCT ALARM <br />Ll(.-iUjj) SENSOR ALPIS <br />L 3:FUEL ALARM - <br />L 3:SENSOR OUT ALARM <br />L 3:SHORT ALARM <br />R 3:87 RELAY <br />T'Y'PE : <br />STANDARD <br />NORMALLY CLOSED <br />IN -TANK ALARMS <br />T 3:LEAY ALARM <br />T 3:HIGH WATER ALARM <br />T 3:LOW PRODUCT ALARM <br />LIGUID SENSOR ALMS <br />L 5:FUEL ALARM <br />L 5:SENSOR OUT ALARM <br />L 5:SHORT ALARM <br />R 4:DIESEL RELAY <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />IN -TANK ALARMS <br />T 4:LEAK; ALARM <br />T 4:HIGH WATER ALARM <br />T 4:1 -OW PRODUCT ALARM <br />LIGUID SENSOR ALMS <br />L 7:FUEL ALARM <br />L 7:,SENSOR OUT ALARM <br />L 7:SHORT ALARM <br />R 5:OVERFILL ALARM <br />TYPE: <br />STANDARD <br />NORMALLY OPEN <br />IN-TANX ALARMS <br />ALL:OVERFILL ALARM <br />