My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 1:24:34 PM
Creation date
6/23/2020 6:44:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2010
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_2008-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ONIT NG SYSTEM CETI CATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> • This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to <br /> the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: CRLLC#2705447 FB—1d g. No.: <br /> Site Address: 1469 E.HAMMER LANE Cit : STOCKTON I Zip: 95209 <br /> Facility Contact Person: ARMEN MKRTYTCH/AN Contact Phone No.: (925)884-080 <br /> Make/Model of Monitoring System: VEEDER-ROOT TLS-350 Date of Testing/Servicing: JUL 19, 2010 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment inspected/serviced: <br /> Tank ID:91 Tank ID:89 <br /> Z In-Tank Gauging Probe. Model:MAG Z In-Tank Gauging Probe. Model:MAG <br /> Z Annular Space or Vault Sensor. Model:409 Z Annular Space or Vault Sensor. Model:409 <br /> Z Piping Sump/Trench Sensor(s). Model:208 Z Piping Sump/Trench Sensor(s). Model:208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model:LD 2000 Z Mechanical Line Leak Detector. Model:FXIV <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Z Tank Overfill/High-Level Sensor. Model:FLOAT/FLAPPER Z Tank Overfill/High-Level Sensor. Model:FLOAT/FLAPPER <br /> ❑Other(specify e ui ment e and model in Section Eon Pa e 2). ❑ Other(speciLy a ui ment ty e and model in Section E on Pa e 2 . <br /> Tank ID:87 Tank ID:DIESEL <br /> Z In-Tank Gauging Probe. Model:MAG ®In-Tank Gauging Probe. Model:MAG <br /> Z Annular Space or Vault Sensor. Model:409 Z Annular Space or Vault Sensor. Model:409 <br /> Z Piping Sump/Trench Sensor(s). Model: 208 Z Piping Sump/Trench Sensor(s). Model:208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model:LD 2000 Z Mechanical Line Leak Detector. Model:LD 2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Z Tank Overfill/High-Level Sensor. Model:FLOAT/FLAPPER Z Tank Overfill/High-Level Sensor. Model:FLOAT/FLAPPER <br /> ❑Others eci equipment e and model in Section E on Pae 2). ❑Other(specify equipment e and model in Section E on Pae 2). <br /> Dispenser ID: 102 Dispenser ID:33=4 <br /> Z Dispenser Containment Sensor(s). Model:BEAUDREAU Z Dispenser Containment Sensor(s). Model:BEAUDREAU <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> Z Dispenser Containment Floats and Chain (s). Z Dispenser Containment Floats and Chain (s). <br /> Dispenser ID:556 Dispenser ID: 7758 <br /> Z Dispenser Containment Sensor(s). Model:BEAUDREAU Z Dispenser Containment Sensor(s). Model:BEAUDREAU <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> Z Dispenser Containment Floats and Chain (s). Z Dispenser Containment Floats and Chains . <br /> Dispenser ID:9-10 Dispenser ID: <br /> Z Dispenser Containment Sensor(s). Model:BEAUDREAU ❑Dispenser Containment Sensor(s). Model: <br /> Z Shear Valve(s). ❑Shear Valve(s). <br /> Z Dis enser Containment Floats and Chain(s). I ❑Dis enser Containment Floats and Chains . <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to the Certification is information(e.g. manufacturers' checklists)necessary to verify that this information is correct and a <br /> Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the <br /> report; (check all that apply): ® System set-up Z Alarm history report <br /> _7Technician Name(print): MIKE LAWRENCE Si nature: <br /> Certification No:A26642 License: 803705 <br /> Testing Company Name: TANK-TEK ENVIRONMENTAL CORPORATION I Phone No: (707)446-6151 <br /> Address: 607 ELMIRA RD,PMB 336, VACAVILLE, CA 95687 Date of Testing/Servicing: JUL 19,2010 <br /> Page 1 of 3 <br /> Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.