Laserfiche WebLink
N/CNOL06Y- NOE <br />A&ONITORING SYSTEM CERTIFICATION <br />PqWe By All Jurisdictions Within the State of Califomi <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3 Title 23,Ca rtornia Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: CANEPA CAR WASH <br />Site Address: 642 N HUNTER <br />Facility Contact Person: PAUL CANEPA <br />Make/Model of Monitoring System: TLS -350 <br />B. Inventory of Equipment Tested/Certified <br />City: STOCKTON CA Zip: 95202 <br />Contact Phone No: 948-1636 <br />Date of Testing/Service: 10/07/2004 <br />Work Order Number: 2232543 <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />Tank ID: SUPREME <br />Tank ID: REGULAR <br />%< In -Tank Gauging Probe. <br />Model: MAG 1 <br />El In -Tank Gauging Probe. <br />Model: MAG 1 <br />X Annular Space or Vault Sensor. <br />Model: 420 <br />Annular Space or Vault Sensor. <br />Model: 420 <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Lai Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: VR <br />%< Electronic Line Leak Detector. <br />Model: VR <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />0 Other (specify equipment type and model in Section E on page 2). <br />Tank ID: <br />Tank ID:. <br />X In -Tank Gauging Probe. <br />Model: MAG 1 <br />® In -Tank Gauging Probe. <br />Model: MAG 1 <br />X Annular Space or Vault Sensor. <br />Model: 420 <br />Annular Space or Vault Sensor. <br />Model: 420 <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Fill Sump Sensor(s). <br />Model: <br />Q Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />El Mechanical Line Leak Detector. <br />Model: <br />X Electronic Line Leak Detector. <br />Model: VRVR <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Dispenser : 1/3 <br />Dispenser ID: 2/4 <br />® Dispenser Containment Sensor(s) <br />Model: 001 <br />X❑ Dispenser Containment Sensor(s) <br />Model: 001 <br />XD Shear Valve(s). <br />X Shear Valve(s) <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Ej Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5/7 <br />Dispenser ID: 6/8 <br />RI Dispenser Containment Sensor(s) <br />Model: 001 <br />Dispenser Containment Sensor(s). <br />Model: 001 <br />® Shear Valve(s). <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9/11 <br />Dispenser ID: 10/12 <br />❑X Dispenser Containment Sensor(s) <br />Model: 001 <br />X Dispenser Containment Sensor(s). <br />Model: 001 <br />® Shear Valve(s).X1771 <br />Shear Valve(s). <br />® Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />* If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): System set-up report; R Alarm history report X❑ <br />PRINTED NAME:ROBERT SANTOS SIGNATURE: <br />COMPANY: Tanknology PHONE NO: <br />page 1 of 3 <br />(800) 800-4633 <br />Based on CA form dated 03/01 <br />