COMPLIANCE INFO_2009-2012 DOUBLE CHECK
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9321
>
2300 - Underground Storage Tank Program
>
PR0231261
>
COMPLIANCE INFO_2009-2012 DOUBLE CHECK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:56:44 PM
Creation date
6/23/2020 6:45:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012 DOUBLE CHECK
RECORD_ID
PR0231261
PE
2361
FACILITY_ID
FA0002890
FACILITY_NAME
QUIK STOP MARKET #2120*
STREET_NUMBER
9321
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
080-180-05
CURRENT_STATUS
01
SITE_LOCATION
9321 N THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231261_9321 N THORNTON_2009-2012 DOUBLE CHECK.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
287
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANNUAL IPILL CONTAINER TESDREPORT <br /> TEST DATE: May 18, 2010 <br /> Al. FACILITY A2. OWNER <br /> Name Quik Stop Market#120 Name Quik Stop Markets, Inc. <br /> Address 9321 Thornton Road,Stockton,CA 95209 Address 4567 Enterprise Street,Fremont,CA 94538 <br /> Phone# 510-657-8500 Phone# 510-657-8500 <br /> Contact Michael Karvelot Contact Michael Karvelot <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E. Main Street,Stockton,CA 95202 Address P.O. Box 1025,W.Sacramento,CA 95691 <br /> Notified May 12,2010 Lic# 617238 A,B,Haz <br /> Inspector Garrett Backus Contact Richard Walton <br /> Phone# 209-468-8257 Phone# 916-825-3203 <br /> K. SPILL CONTAINER TEST RESULTS <br /> Measuring Equipment Used: Caldwell System 2001 /Walton Engineering (Level Change Indicator) <br /> Tank Number 1 2 <br /> Product contained Gasoline-87 Gasoline-91 <br /> Spill container capacity (US gallons) 5 5 <br /> Spill container manufacturer OPW OPW <br /> Spill container depth (inches) 13.00 13.00 <br /> Is the spill container located in a sump? Yes Yes <br /> Does sump have a liquid sensor installed? No No <br /> Condition of spill container prior to testing Dry Dry <br /> Portion of spill container tested Entire Entire <br /> Depth of water level from bottom (inches) 11.50 11.50 <br /> Wait time for water level to stabilize (hr:min) 0:05 0:05 <br /> Test start time 9:13 9:09 <br /> Test end time 9:43 9:39 <br /> Test duration (hr:min) 0:30 0:30 <br /> Change in water level (t 0.000 inches) 0.000 0.000 <br /> Pass/Fail threshold (0.005 inches/1A Hr.) 0.005 0.005 <br /> TEST RESULT PASS PASS <br /> L. COMMENTS: <br /> WALTON <br /> Signature: < <� -�� <br /> ENGINEERING,INC, <br /> Technician: Gerardo Guzman/B35394 5242481-UT Date: May 18,2010 <br /> ©2010 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.