My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012 DOUBLE CHECK
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9321
>
2300 - Underground Storage Tank Program
>
PR0231261
>
COMPLIANCE INFO_2009-2012 DOUBLE CHECK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:56:44 PM
Creation date
6/23/2020 6:45:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012 DOUBLE CHECK
RECORD_ID
PR0231261
PE
2361
FACILITY_ID
FA0002890
FACILITY_NAME
QUIK STOP MARKET #2120*
STREET_NUMBER
9321
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
080-180-05
CURRENT_STATUS
01
SITE_LOCATION
9321 N THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231261_9321 N THORNTON_2009-2012 DOUBLE CHECK.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
287
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYMEM SET-UP REPORT age 1) <br /> COMMUNICATIONS SETUP <br /> SYSTEM SETUP <br /> - - - - - - - - - - - - SYSTEM SEC UR I TY - - - - - - - - <br /> HH,, 18. 2010 8:42 AM CODE : 000000 <br /> MAINTENANCE HISTORY PORT SETTINGS; <br /> DISABLED COMM BOARD 1 (RS-232) <br /> SYSTEM UNITS BAUD RATE 1200 <br /> U.S. PARITY ODDSYSTEM LANGUAGE TANK CHART SECURITY <br /> STOP BIT 1 STOP <br /> ENGLISH DISABLED DATA LENGTH: 7 DATA <br /> .SYSTEM DHTE,TIME FORMAT RS-232 SECURITY <br /> MON DD YY'fY HH:MM:SS xM CUSTOM ALARMS CODE : DISABLED <br /> QUIK STOP 120 DISABLED COMM ONIM BOARD 2 (RS-232) <br /> 9311 THORNTON RD. BAUD RATE 9600 <br /> STOCKTON,CA. .95207 PARITY NONE <br /> 209-478-7149 SERVICE NOTICE STOP BIT 2 STOP <br /> DISABLED DATA LENGTH: 8 DATA <br /> SHIFT TIME 1 DISABLED RS-232 SECURITY <br /> SHIFT TIME 2 DISABLED <br /> SHIFT TIME 3 DISABLED ISO 3166 COUNTRY CODE DISABLED SHIFT TIME 4 DISABLED CODE: COMM BOARD : 3 (EDIM ) <br /> RS-232 SECURITY <br /> TANK PER TST NEEDED WRN MASS/'DEhJS I TYCODE : <br /> DISABLED DISABLED D I SABLED <br /> TANK ANN TST NEEDED WRN - - COMM BOARD 5 (S-SAT ) <br /> DISABLED BAUD RATE 9600 <br /> OUTPUT RELAY SETUP PARITY NONE <br /> LINE RE-ENABLE METHOD - - - - - - - - - - - STOP BIT 2 STOP <br /> PASS LINE TEST DATA LENGTH: 8 DATA <br /> R 1 :91 STP RS-232 SECURITY <br /> LINE PER TST NEEDED WRN T'A'PE: CODE : DISABLED <br /> DISABLED STANDARD DTR NORMAL STATE: HIGH <br /> LINE ANN TST NEEDED WRN NORMALLY CLOSED <br /> DISABLED <br /> PRINT TC VOLUMES TANK 0: 2 AUTO TRANSMIT SETTINGS: <br /> ENABLED AUTO LEAK ALARM LIMIT <br /> LIQUID SENSOR ALMS DISABLED <br /> TEMP COMPENSATION L3:FUEL ALARM AUTO HIGH WATER LIMIT <br /> VALUE (DEG F ) : 60.0 L 3:SENSOR OUT ALARM DISABLED <br /> STICK HEIGHT OFFSET L 3:SHORT ALARM AUTO OVERFILL LIMIT <br /> DISABLED DISABLED <br /> ULLAGE: 90% ISD SITE ALARMS AUTO LOW PRODUCT <br /> ISD GROSS PRES FAIL DISABLED <br /> H-PROTOCOL DATA FORMAT ISD DEGRD FRES FAIL AUTO THEFT LIMIT <br /> HEIGHT ISD VAPOR LEAK FAIL DISABLED <br /> DAYLIGHT SAVING TIM£ ISD VP PRES FAIL AUTO DELIVERY START <br /> ENABLED ISD VP STATUS FAIL DISABLED <br /> START DATE AUTO DELIVERY END <br /> MAR WEER: 2 SUN ISD HOSE ALARMS DISABLED <br /> START TIME ALL:FLOW COLLECT FAIL AUTO EXTERNAL INPUT ON <br /> 2:00 AM DISABLED <br /> END DATE R 2:87 STP AUTO EXTERNAL INPUT OFF <br /> NOV WEEK 1 SUN TYPE: DISABLED <br /> END TIME STANDARD AUTO SENSOR FUEL ALARM <br /> 2:00 AM NORMALLY CLOSED DISABLED <br /> AUTO SENSOR WATER ALARM <br /> RE-DIRECT LOCAL PRINTOUT TANK 0: 1 DISABLED <br /> DISABLED AUTO SENSOR OUT ALARM <br /> DISABLED <br /> EURO PROTOCOL PREFIX LIQUID SENSOR ALMS - <br /> S L 4:FUEL ALARM SMARTSENSOR SETUP <br /> L 4:SENSOR OUT ALARM - - - - - - - - - - - _ <br /> LEAK TEST METHOD L 4:SHORT ALARM s I :DISP 1-2 AFM <br /> TEST ON DATE ALL TANK ISD SITE ALARMS CATEGORY AIR FLOW METER <br /> OCT 9, 2008 ISD GROSS PRES FAIL <br /> START TIME : DISABLED ISD DEGRD PRES FAIL s :?•DISE' 3-4 AFM <br /> ISD VAPOR LEAK FAIL CATEGORY AIR FLOW METER <br /> TEST RATE :0.20 Gr~L;'HR ISD VP PRES FA I L <br /> DURATION : 2 HOURS ISD VP STATUS FAIL s 3:VAPOR PRESSURE <br /> TST EARLY STOP:DISABLED ISD HOSE ALARMS CATEGORY VAPOR PRESSURE <br /> LEAK TEST REPORT FORMAT ALL:FLOW COLLECT FAIL s 4;V.R. POLISHER <br /> NORMAL CATEGORY VAPOR VALVE <br /> s 8:ATM <br /> CATEGORY ATM R SENSOR <br /> ©2010 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.