My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 4:20:10 PM
Creation date
6/23/2020 6:45:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_2013-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
This Spill Bucket Testing Report Form -es. The conipleh I./orin and <br />firin is infendedjbr use bil contractors perlbrtning annual testing of UST spill containment structures. -egulatort agency. <br />printouts from tests (if applicable), should be provided to lhepcilh�� ownerl'operatorfbi- submittal to the local i <br />qrl"V <br />FacilityName: GEORGE KISH IDA TRUCKING Date of Testing: 11/20/2015 <br />Facility Address: 1725 ACKERMAN DR City: LODI <br />Facility Contact: KELLI Phone: 209-368-0603 <br />Date Local Agency Was Notified of Testing: Monday, August 24, 2015 <br />Name of Local Agency Inspector (if present during testing): ARIS VELOSO <br />2. TESTING CONTRACTOR INFORMATION <br />Company Name: BZ Service Station Maintenance <br />Technician Conducting Test: RHOME DESDIENS <br />0- -1 j <br />credentialsi.. CSLB Conti -actor ICC Service Tech. ❑ SWRCBTankTester Other (Spec�/,-) <br />License Number(s): 433159 <br />s carr IF 1n1rT1-1ZVVrVVQ9r1r0&- 11XJVnDX4A9r1nV <br />—Test Method Used: <br />Hydrostatic <br />❑ Vacuum <br />El Other <br />Test Equipment Used: RULER <br />Equipment Resolution: <br />1/16" <br />3 <br />4 <br />Identify Spill Bucket (8y Tank <br />I T5 - DSL 2 T6 -DSL <br />Number, Stored Product, etc.) <br />Installation Type: <br />Z Direct Bury <br />E] Contained in Sump <br />M Direct ffu-ry— <br />❑ Contained in Sump <br />El Direct Bury <br />El Contained in Sump <br />D vct BuryBucket <br />—E] Conta ned in Sump <br />Bucket Diameter: <br />11- <br />11" <br />Bucket Depth: <br />1719 <br />17" <br />Wait time between applying <br />vacuum/water and start of test: <br />5 MIN <br />5 MIN <br />Test Start Time (Ti): <br />10:00 <br />11:10 <br />Initial Reading (111): <br />16'— <br />16" <br />Test End Time (TF): <br />11:00 <br />12:10 <br />ULLI <br />Final Reading (RF): <br />16" <br />16" <br />T <br />Test Duration (TI., - Tj): <br />I HR <br />I HR <br />m <br />Change in Reading (RF - Rj): <br />0 <br />0 <br />Pass/Fail Threshold or <br />Criteria: <br />0 <br />0 <br />Test Result: <br />ED Pass E] Fall <br />[D Pass E] Fail <br />El Pass [I Fail <br />Fail <br />Comments - (inchide iiffiortitation on repairs made prior to testing, and recommended ft)11oiv-tqifor ,failed 1(:;ts) <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal require nents. <br />Technician's Signature: Date: 11/20/2015 <br />State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requiremer Is may be more <br />stringent. <br />Monitoring Certification Test Report <br />4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.