Laserfiche WebLink
V SGSSGS U.S. TestingCompany p Y Inc. <br /> 291 Fairfield Avenue REPORT NUMBER: 112282-11 <br /> Fairfield, NJ 07004 DATE: May 17, 1996 <br /> Tel: 201-575-5252 <br /> Fax: 201-575-8271 PAGE 1 OF 11 <br /> CLIENT: Industrial Environmental Coatings Corp. <br /> 1831 Blount Road <br /> Suite B <br /> Pompano Beach, FL 33069 <br /> ATTN: Paul Meli, Jr. <br /> SUBJECT: Physical Properties <br /> V J <br /> L1.1 AUTHORIZATION: Industrial Environmental Coatings Corp., Order for Test dated August <br /> 15, 1994 <br /> SAMPLE ID: One (1) sample of material was received from the Client. It was <br /> L submitted on more than one day. The Client identified the sample as: <br /> Epoxy Coating EC 1250: The sample was received in acceptable <br /> C condition. i <br /> TEST PROCEDURE: The submitted sample was tested for the following properties in <br /> �-�- accordance with the procedures outlined in the ASTM Test Methods <br /> listed below. The tests were performed Before and After Immersion in <br /> the reagents indicated. All immersions were conducted at 73°F. <br /> Q 1• Coefficient of Linear Thermal Ex <br /> a. 2• Change in Dimensions and Weightnslon ASTM D-696-91 <br /> [�(j 3• Flexural Properties g ASTM D-543-87 <br /> 4• Barcol Hardness ASTM D-790-92 <br /> ASTM D-2583-92 <br /> 5• Bond Strength to Steel <br /> Standard Lab <br /> 6• Impact Resistance Procedure <br /> ASTM D-2794-92 <br /> PREPARED BY: SIGNED FOR THE COMPANY BY: <br /> Frank Savino, Manager <br /> Frank Pepe, Director <br /> Engineering Physical Properties <br /> nJp Standards Testing & Material Evaluation <br /> Member of the SGS Group <br /> ANALYTICAL SERVICES - PERFORMANCE TESTING - STANDARDSI EVALUATION - CERTIFICATION SERVICES <br /> SGS U.S.TESTING COMPANY INC.REPORTS ARE FOR THE EXCLUSIVE USE OF THE CLIENT TO WHOM THEY ARE ADDRESSED.ANYONE RELYING. <br /> ON SUCH REPORTS SHOULD UNDERSTAND ALL OF THE DETAILS OF THE ENGAGEMENT.REPORTS REFLECT RESULTS ONLY OF THE STANDARDS <br /> OR PROCEDURES IDENTIFIED TO THE TESTS CONDUCTED AND ARE LIMITED TO THE SAMPLES TESTED.TEST RESULTS MAY NOT BE INDICATIVE <br /> OF THE QUALITIES OF THE LOT FROM WHICH THE SAMPLE WAS TAKEN,SGS U.S.TESTING COMPANY INC.HAS NOT CONDUCTED ANY QUALITY <br /> CONTROL PROGRAM FOR THE CLIENT NEITHER THE NAME,SEALS.MARKS NOR INSIGNIA OF SGS U.S.TESTING COMPANY INC.MAY BE USED IN <br /> ANY ADVERTISING OR PROMOTIONAL MATERIALS WITHOUT THE PRIOR WRITTEN APPROVAL OF SGS U.S.TESTING COMPANY INC. THIS REPORT <br /> SHALL NOT BE REPRODUCED EXCEPT IN FULL WITHOUT THE WRITTEN PERMISSION OF THE SGS U.S TESTING COMPANY INC. SAMPLES NOT <br /> DESTROYI70 IN TESTING ARE DISPOSED OF AFTER 30 DAYS. <br />