Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Y£yC'/�w!{M <br />(�� CIAO <br />'L-..^+a,�.. i+�:Si"1Q£'ks'. i_^«-»"iA�R,:: Pl�i, by.,�• 'i"„+�.,Fgbk�*' <br />F <br />Facility Name: <br />VAN DE POL ENT INCIPACIFIC PRIDE <br />Facility Address: <br />351 N BECKMAN RD LODI <br />Date: <br />June 27 2017 <br />Ifrt POO0,0atiens; q¢ <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />❑ V ❑ R ❑ COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V ❑ R ❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R ❑ COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R ❑ COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V ❑ R ❑ COS <br />4 SlQ <br />.,. ge�I1ClluPressuFlza{,{ f?,iP�ng' <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />��L�IisltlO�i1S <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R ❑ COS <br />ON RY OF, VIOLATIoINS <br />(Gi�4SS,CkASS I�, of ^MMoR hotrc to Eompty� <br />11 <br />Item # <br />Remarks <br />104 <br />CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />The UST Tank Information for all the tanks are not current in the California Environmental Reporting System (CERS). <br />The riser pipe secondary containment states "none" in the Fill Pipe Piping Construction section. Please change to <br />"fiberglass" since all the tank riser pipes for receiving fuel are contained within fiberglass sumps. <br />Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br />update the required information, and submit for review by the EHD. <br />This is a Class II violation. <br />Page 3 of 5 <br />