My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 4:33:55 PM
Creation date
6/23/2020 6:46:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.;11FA F. Z.rpl 0 <br />San Joaquin County, Z�- <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siciov.orq/ehd <br />� ' <br />U'l <br />nround e'1aa�Stor <br />gpn�p� Rrt <br />..n w <br />p t <br />Facility Name: <br />Facility Address: <br />Date: <br />VAN DE POL ENT INC/PACIFIC PRIDE <br />351 N BECKMAN RD LODI <br />June 24 2016 <br />'.f Y k' k, ' < 4 � . 4 M 'a:: •fI °�. G' ti .,y 's..#i # nP"' R*A. Cr4b:* - �4 6y°s A '� H"s,'��#` ky.n <br />UST System Observationsr 51FaFz <br />a 4 <br />326 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />327 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />329 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V ❑ R ❑ COS <br />on Pressurised " <br />"N? <br />99- "A, <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />yt <br />Oher�Vtolatlons y g <br />x <br />-§ ��qe <br />33� 2 4 + z .� Tr°"� �!YUPc °.dk'YF bay}.3.Ee <br />a. k <br />2010 <br />See below <br />Unlisted Administration/Documentation violation ■ V ❑ R ❑ COS <br />2030 See below <br />Unlisted Operations/Maintenance violation ❑ V ❑ R ❑ COS <br />2060 See below <br />Unlisted Design/Construction violation ❑ V ❑ R ❑ COS <br />M A <br />S.. - } VV/RA <br />Item # <br />Remarks <br />105 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The monitoring plan is not current and not approved by the EHD. The diesel AB annular sensor model number is <br />listed as 420, but should be listed as 460. The monitoring plan must be uploaded to the California Environmental <br />Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit for review by the <br />EHD. <br />This is a repeat violation, Class II. <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. The monitoring plan is not current and not <br />approved by the EHD. The diesel AB annular sensor model number is listed as 420, but should be listed as 460. A <br />copy of these plans shall be accessible on site at all times. Immediately locate and retain a an approved copy on <br />site. <br />This is a minor violation. <br />Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.