My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 4:33:55 PM
Creation date
6/23/2020 6:46:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WWSan Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (y209) 468-3433 Web: www.sjgov.or /q ehd <br />tt <br />4 J"�'SG i +n u .✓Sy,.�+^i.. R'�'zd' '`K6 `k ... "#34?` 7 i <br />g �, aUn er o d SS ora aTal�k§I'ro raI s =18R ort <br />Facility Name: <br />Facility Address: <br />Date: <br />VAN DE POL ENT INCIPACIFIC PRIDE <br />351 N BECKMAN RD LODI <br />June 24 2016 <br />Y '$ t ft <br />�6z x SUMM RY O UIOATIONS ¢�� <br />'iWFdd �'b"° .I.." t e 2`i <br />.o.+"f.T�cn.. �EF... t .L1+���'✓' 'aafi'fh �:ttt'i ;i.n ,.ih ex'. <br />ICLgSS,'II o MI 012 of c��toCompl 1.r <br />Item # <br />Remarks <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator documented all the alarms from the attached alarm history on the 4-26-16 and 12-4-15 <br />designated operator monthly inspection reports but failed to check that they were responded to appropriately. The <br />alarm responses are lacking for the following: 3-31-16 L1 Red Diesel Fill fuel alarm and 11-24-15 L2 91 Fill alarm. <br />During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br />that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. <br />This is a repeat violation, Class II. <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 87 VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting <br />a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it passed. <br />This is a repeat violation, Class II. <br />2010 <br />CCR 2712(i) Prior to the routine inspection, Marty Thorpe called to inform the SJCEHD that concrete had been broken <br />and replaced over the 91 UST and that a permit had not been obtained for this work. A copy of the permit and all <br />conditions and attachments, including monitoring plans, shall be retained at the facility. Construction, repair and/or <br />removal permits are required from the EHD prior to any change, repair, or removal of UST system equipment. A failure <br />to obtain permit penalty (double permit fee) applies. Correct immediately by including the failure to obtain permit <br />penalty fee with your permit application. <br />This is a minor violation. <br />Overall Inspection Comments: <br />An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br />complete report which replaces the initial checklist. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days of receiving the complete inspection report. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br />FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: <br />Date: <br />Inspector: <br />Inspector Phone: <br />6 G Printed Name and Title: <br />ok-�A rGW�`l <br />ARIS VELOSO, Senior REHS <br />(209) 468-3453 <br />Page 4 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.