My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 4:33:55 PM
Creation date
6/23/2020 6:46:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1"] <br />0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sagov.org/ehd <br />CONTINUATION FORM <br />Page: 5 of 6 <br />OFFICIAL INSPECTION REPORT <br />Date: 06/30/14 <br />Facility Address: Van de Pol Pacific Pride 351 N. Beckman Rd. Lodi, CA 95240 <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />204. The designated operator failed to document responses to all the alarms from the attached alarm <br />history on the 10-4-13 and 8-1-13 designated operator monthly inspection reports. The missing alarm <br />responses are lacking for the L2 91 fill sump sensor 9-21-13 alarm, L7 91 turbine sump sensor 9-21-13 <br />alarm, L11 Red diesel annular sensor 7-24-13 alarm, and L14 diesel annular sensor alarm. Alarm history <br />reports attached to the designated operator reports were incomplete. The 4-10-14 D.O. report lacked the <br />C1 87 annular alarm history print out. The 1-20-14 D.O. report lacked the L6 Red diesel turbine sump <br />alarm history print out. The 12-2-13 D.O. report lacked the L4 diesel fill, L7 91 turbine sump, L9 diesel <br />turbine sump, L14 diesel annular, and C1 87 annular alarm history reports. The 7-1-13 D.O. report <br />lacked the entire alarm history report. The During the monthly inspection, the designated operator shall <br />review the alarm history for the previous month, check that each alarm was documented and responded <br />to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br />alarms to the monthly report. Ensure that designated operators performing monthly inspections at this <br />facility are including all of the required information on the reports. <br />306. A fuel leak was found at the diesel filters in dispensers 1/2 and 3/4. All primary containment must <br />be product tight. Immediately have a properly licensed, trained, and certified contractor replace or <br />tighten the fuel filter. <br />311. The 91 and diesel "A" line leak detector failed to detect a leak when tested. All line leak detectors <br />shall be capable of detecting a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak <br />detector, retested it, and it passed. <br />311. The 87 line leak detector failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, <br />and certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and <br />obtain a permit within one business day from the EHD. If the failed leak detector can't be replaced <br />immediately, there is a possibility that the 87 UST system may be red tagged to prevent fuel inputs. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJEqJj.9 REINSPECTION AT ANY TIME kT END'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Receiv By <br />Title: <br />Aris Veloso (209) 468-3453 <br />e v" <br />EHD 23-02-003 Rev 04/19/12 U CONTINOATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.