PE
2361
FACILITY_ID
FA0004139
FACILITY_NAME
Plaza liquor and Gas
STREET_NUMBER
2420
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95242
CURRENT_STATUS
01
SITE_LOCATION
2420 W TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231382_2420 W TURNER_1998-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
474
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.2/22/2009 15:12 2093651 TANKNOLOGY <br />SWRCB January 2002 <br />Was sensor removed for testing? I X jYej,..._JNNA Ye .N NH T es <br />Was sensor properly replaced and x Ye N A x Ye N NA Ye N NA <br />verified functional after testing? ❑ `� <br />Comments - Onclude information on repairs made prior to testing, and recommended follow -zip for failed <br />PAGE 02/06 <br />Page 2. <br />Engineer <br />■ WN -0 <br />NCNA <br />I <br />t Secondary containment systems where the continuous monitoring automatically monitors both the primary an� secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from pe4odie containment <br />testing, {California Code of Regulations, Title 23, Section. 2637(x)(6)} <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: <br />Tank Manufacturer <br />1x Industry Standard <br />El F <br />Other (Spec(fy) <br />Pressure <br />El Vacuum <br />❑ h <br />Test Method Used: <br />Other (Specify) <br />Equipment Resolution: <br />Test Equipment Used: <br />-- I III I <br />ffi�jji <br />11=11111i oil <br />Tank N. 1 REG <br />Tank # 3 DIE Tank # <br />Is Tank Exempt From Testing?Yes <br />No <br />Lj <br />Yes <br />X No <br />Yes <br />LlNo <br />Tank Capacity: <br />10,000 <br />10,000 <br />Tank Material: <br />DW STEEL <br />DW STEEL <br />Tank Manufacturer: <br />unknown <br />unknown <br />Product Stored: <br />REGULAR <br />DIESEL <br />Wait time between applying <br />pressure/vacuum/water and <br />5miat <br />5min <br />starting test: <br />-�—�— <br />Test Start Time: <br />% : 4 0 <br />11:5 4 <br />Initial Reading (Ri }: <br />7hg <br />7hg <br />Test End Time: <br />10:40 <br />12:54 <br />Final Reading (RF <br />7hg <br />7hg <br />Test Duration: <br />1hr <br />1hr <br />Change in Reading (RF - Rt }: <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />1.7hg <br />1.7hg <br />Was sensor removed for testing? I X jYej,..._JNNA Ye .N NH T es <br />Was sensor properly replaced and x Ye N A x Ye N NA Ye N NA <br />verified functional after testing? ❑ `� <br />Comments - Onclude information on repairs made prior to testing, and recommended follow -zip for failed <br />PAGE 02/06 <br />Page 2. <br />Engineer <br />■ WN -0 <br />NCNA <br />I <br />t Secondary containment systems where the continuous monitoring automatically monitors both the primary an� secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from pe4odie containment <br />testing, {California Code of Regulations, Title 23, Section. 2637(x)(6)} <br />
The URL can be used to link to this page
Your browser does not support the video tag.