My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231382
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 2:12:56 PM
Creation date
6/23/2020 6:46:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231382
PE
2361
FACILITY_ID
FA0004139
FACILITY_NAME
Plaza liquor and Gas
STREET_NUMBER
2420
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95242
CURRENT_STATUS
01
SITE_LOCATION
2420 W TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231382_2420 W TURNER_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN,tJOAQUIN Environmental Health Department <br />Facility Name: <br />Plaza liquor and Gas <br />Facility Address: <br />2420 W TURNER RD, LODI <br />Date: <br />October 11, 2018 <br />315 <br />HSC 25291 (e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) <br />s V <br />Ei R <br />n COS <br />316 <br />HSC 25290. 1 (c3), <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) <br />V <br />o R <br />o COS <br />317 <br />CCR 2636, 2643(c)(1), <br />Line leak detector (LLD) not installed <br />Ei V <br />o R <br />o COS <br />318 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch <br />Ei V <br />o R <br />o COS <br />319 <br />CCR 2635, 2637. 1, <br />.2665,2712 <br />No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested <br />m V <br />n R <br />o COS <br />320 <br />CCR 2635, 2637.2, <br />12665,2712 <br />Failure to comply with the installation, inspection, or record keeping of the overfill prevention <br />o V <br />Ei R <br />o COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />o V <br />o R <br />o COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />o V <br />o R <br />o COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />o V <br />c R <br />o COS <br />324 <br />CCR 2717.1 (g) <br />Tampered with red tag <br />o V <br />c R <br />o COS <br />325 <br />CCR 2717.1 <br />Deposited petroleum into a red tagged LIST <br />o V <br />o R <br />ci COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />o V <br />c R <br />o COS <br />327 <br />CCR 2631.1 <br />LIST system not compatible with the substance stored <br />o V <br />o R <br />o COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />o V <br />o R <br />o COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />n V <br />o R <br />o COS <br />330 <br />CCR 2636(f), 2666(c), <br />No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm <br />o V <br />Ei R <br />ii COS <br />331 <br />CCR 2630(d), 2641 (a) <br />Liquid does not flow into the sump in the event of a leak (i.e., failure to remove test boot). <br />u V <br />Ei R <br />Ej COS <br />332 <br />CCR 2631 (b&d), <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />o V <br />o R <br />o COS <br />333 <br />CCR 2635, 2636(b), <br />2662,2712 <br />Failure to comply with the cathodic protection system requirements <br />V <br />o R <br />o COS <br />334 <br />CCR 2666(b)(2) <br />Single -walled pipe not upgraded to double -walled interstitially monitored pipe during repair <br />ii V <br />o R <br />o COS <br />335 <br />CCR 2630, 2632,2643, <br />2644.1 <br />Equipment or methods used to monitor the UST system are not certified by an independent third -party <br />V <br />u R <br />o COS <br />401 <br />CCR 2636(a)(3). <br />Suction piping not properly sloped or incorrectly located check valve <br />oV <br />oR <br />o COS <br />402 <br />CCR 2643(d) <br />No monitoring or record maintenance for single -walled conventional suction systems (pre -Jan 1984). <br />oV <br />oR <br />c COS <br />403 <br />CCR 2643(d), 2661(f) <br />Failure to conduct 0.1 gph test for single -walled conventional suction systems (pre -Jan 1984) <br />EiV <br />oR <br />o COS <br />404 <br />CCR 2643(e), 2661 (f) <br />Biennial 0.1 gph line integrity test for single -walled gravity piping not performed (pre -Jan 1984) <br />EiV <br />oR <br />o COS <br />ns <br />2010 <br />See below <br />TUnfsted General violation <br />o V <br />o R <br />ii COS <br />item # <br />Remarks <br />EHD 23-01 Rev. 09/28/2018 Page zm* Underground Storage Tank Program mn <br />18O8E.Hazelton Avenue I Stockton, California Q52O51 T 209488'342O1 F 209 464-0138 1 vmww.sjoand.num <br />
The URL can be used to link to this page
Your browser does not support the video tag.