COMPLIANCE INFO_2003-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2003-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 1:21:27 PM
Creation date
6/23/2020 6:46:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2004
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231404_15 E GRANT LINE_2003-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.49 <br />SECONDARY <br />LINE TESTING <br />Test Method By: <br />Test Method Uses: <br />Measuring Equipment Used: <br />Manufacturer <br />• Pressure <br />Pressure Gauge <br />• Industry Standard <br />Vacuum <br />(range 0 to 10 psig) <br />Professional Engr. Other (see below) <br />Hydrostatic Other (see below) <br />Description <br />Line #1 <br />Line #2 <br />Line #3 <br />5 <br />Pipe manufacturer <br />Ameron <br />Ameron <br />Ameron <br />9:10 AM <br />Final pressure (psig) <br />Pipe material <br />FRP <br />FRP <br />FRP <br />1:00 <br />1:00 <br />Primary pipe diameter (inches) <br />7' <br />7' <br />2" <br />0 <br />Pass/Fail threshold (psig) <br />Secondary pipe diameter (inches) <br />2f" <br />2%2' <br />2'h" <br />PASS <br />PASS <br />Tank product <br />Gasoline - 87 <br />Gasoline - 87 Siphon <br />Gasoline - 91 <br />Method of secondary pipe isolation <br />Clamshell <br />Clamshell <br />Clamshell <br />of secondary pipe isolation <br />Sump + UDC's <br />Sumps <br />Sump + UDC's <br />Estimated length of piping run (feet) <br />90' <br />17 <br />115' <br />include length of <br />Wait time for pressure to stabilize (hrmin) <br />Comments: <br />0:06 <br />0:07 <br />0:05 <br />Test start time <br />7:50 AM <br />8:00 AM <br />8:10 AM <br />Initial pressure (psig) <br />5 <br />5 <br />5 <br />Test end time <br />8:50 AM <br />9:00 AM <br />9:10 AM <br />Final pressure (psig) <br />5 <br />5 <br />5 <br />Test duration (hr:min) <br />1:00 <br />1:00 <br />1:00 <br />Change in pressure (psig) <br />0 <br />0 <br />0 <br />Pass/Fail threshold (psig) <br />0.5 <br />0.5 <br />0.5 <br />branch runs <br />PASS <br />PASS <br />PASS <br />Wait time for pressure to stabilize (hrmin) <br />Comments: <br />0:06 <br />0:07 <br />0:05 <br />Test start time <br />7:50 AM <br />8:00 AM <br />8:10 AM <br />Initial pressure (psig) <br />5 <br />5 <br />5 <br />Test end time <br />8:50 AM <br />9:00 AM <br />9:10 AM <br />Final pressure (psig) <br />5 <br />5 <br />5 <br />Test duration (hr:min) <br />1:00 <br />1:00 <br />1:00 <br />Change in pressure (psig) <br />0 <br />0 <br />0 <br />Pass/Fail threshold (psig) <br />0.5 <br />0.5 <br />0.5 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />© 2003 Watton Engineering, Inc. <br />