My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2003-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 1:21:27 PM
Creation date
6/23/2020 6:46:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2004
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231404_15 E GRANT LINE_2003-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PIPING SUMP CONTAINMENT TESTING <br />Test Method By: <br />Test Method Uses: <br />Measuring Equipment Used: <br />Manufacturer • Industry Standard <br />Pressure vacuum <br />Level Change Indicator <br />Professional Engr. Other (see below) <br />• Hydrostatic Other (see below) <br />(Caldwell System 20011 Walton Engineering) <br />Description <br />Tank #1 <br />Tank #2 <br />Tank #3 <br />Is system programmed for fail-safe operation? <br />Sump material <br />FRP <br />FRP <br />FRP <br />No <br />No <br />Sump diameter (inches) <br />47' <br />47' <br />47' <br />Yes <br />Was sensor property replaced after testing? <br />Sump depth (inches) <br />41" <br />36" <br />34" <br />Tank product <br />Gasoline - 87 <br />Gasoline - 87 Siphon <br />Gasoline - 91 <br />Environ <br />Depth of water level from tank top (inches) <br />Height from tank top to highest <br />piping penetration <br />11" <br />14" <br />9" <br />9:40 AM <br />8:45 AM <br />Height from tank top to lowest <br />electrical penetration <br />13" <br />10" <br />14" <br />9:10 AM <br />Test duration (hr:min) <br />Method of sump attachment to tank <br />Tank Collar <br />Tank Collar <br />Tank Collar <br />0.000 <br />0.000 <br />Type of sum penetration fittings <br />Pass/Fail threshold (0.005 inches /'h Hr.) <br />0.005 <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Condition of sump prior to testing <br />Comments: <br />Dry <br />Dry <br />Dry <br />Portion of sump tested <br />Entire <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Yes <br />Yes <br />Yes <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor property replaced after testing? <br />Yes <br />Yes <br />Yes <br />Environ <br />Environ <br />Environ <br />Condition of sump prior to testing <br />Comments: <br />Dry <br />Dry <br />Dry <br />Portion of sump tested <br />Entire <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Yes <br />Yes <br />Yes <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor property replaced after testing? <br />Yes <br />Yes <br />Yes <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:07 <br />0:05 <br />Depth of water level from tank top (inches) <br />15" <br />16" <br />16" <br />Test start time <br />9:40 AM <br />8:45 AM <br />8:40 AM <br />Test end time <br />10:10 AM <br />9:15 AM <br />9:10 AM <br />Test duration (hr:min) <br />0:30 <br />030 <br />0:30 <br />Change in water level (± 0.000 inches) <br />0.000 <br />0.000 <br />0.000 <br />Pass/Fail threshold (0.005 inches /'h Hr.) <br />0.005 <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />2003 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.